18
MAINTENANCE
1. Using a small wire brush, reach down the barrel of
the heater and brush the igniter electrode. Ensure
buildup is removed.
2. Verify igniter gap of the igniter electrode. Gap
should be 3/16 in. See Fig. 17.
FIG. 17
3/16 IN. / 4.7 MM

Thermostat

Tradesman 170:
■ Remove the base bottom. Slide the thermostat
bulb through the cable tie. See Fig. 18.
Tradesman 400:
■ Remove a side panel and the fan guard. Open the
bulb rention clip to remove thermostat bulb. See
Fig. 19. Guide the thermostat bulb through the
bushing.
2. Remove knob and thermostat mounting screws
and disconnect its wiring. See Fig. 20.
FIG. 18
BULB
Owner's Manual • Tradesman
THERMOSTAT
FIG. 19
BUSHING
SCREWS
FIG. 20

Ignition Control

1. Disconnect the LED wire harness (if applicable) from
the circuit board.
2. Disconnect the ignition cable and remove the nuts
securing the control to the side of the heater's base.
See Fig. 21.
3. When replacing, use care to prevent damage to the
controller's components.
FIG. 21
LED WIRE
HARNESS
IGNITION CABLE
CLIP
SCREWS
NUT