Thermostat Installation; Manual Shut-Off Valve, Hose And Regulator Assembly - L.B. White AW250 Owner's Manual And Instructions

Agricultural animal confinement building heaters
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect the electrical supply before connecting the
thermostat to the heater.
Failure to follow this warning can result in electrical
shock, leading to personal injury or death.
To Connect the Direct Wired Thermostat Kit to the Control
Box on the Heater:
a. The installation and wiring of a thermostat must
be done by an electrician or someone properly
qualified.
1. Always use approved pipe thread compound suitable
for use with L.P. on the threaded connections.
2. Assemble the components together according to the
figure. This view is to show general assembly of the
components only. The regulator must always be
mounted so its vent, regardless of location on the
regulator, is always pointed downward.
3. Tighten all connections securely.
4. Check all connections for gas leaks using approved
gas leak detectors.
WARNING

THERMOSTAT INSTALLATION

b. The thermostat may use 18 gauge, 2 wire cord to
handle the low voltage being supplied to the
thermostat from the transformer.
c. Follow all instructions provided with the
thermostat kit.
d. The heater must be tested for proper operation
after the thermostat has been connected.
MANUAL SHUT-OFF VALVE, HOSE
AND REGULATOR ASSEMBLY
FIG. 5
REGULATOR VENT
TO CONTROL
VALVE INLET
REGULATOR
NIPPLE
VALVE, MANUAL
SHUT-OFF
GAS HOSE
ADAPTER
SEDIMENT TRAP
10