Page 1
TRADESMAN K350 & K600 HIGH PRESSURE KEROSENE PORTABLE FORCED AIR HEATER (with Thermostat) OWNER’S MANUAL 600 SIDE PV 027 350 SIDE PV 026 Model Number: CP350AK and CP600AK Heater Size: 350,000 and 600,000 Btu/Hr IMPORTANT: Read and understand this manual before assembling, start- ing, or servicing heater.
HIGH PRESSURE PORTABLE FORCED AIR HEATER 350,000 AND 600,000 BTU/HR SAFETY d)During fueling, all fuel lines and fuel- • Minimum heater clearances from com- line connections shall be inspected for bustibles: INFORMATION leaks. Any leaks shall be repaired prior Outlet: 8 Ft. Sides: 4 Ft. to returning the heater to service.
OWNER’S MANUAL PRODUCT UNPACKING IDENTIFICATION Remove all protective packing applied to heater for shipment. Remove heater from shipping con- Hot Air Outlet tainer. 3. Check heater for any shipping damage. Upper Shell If heater is damaged, promptly inform dealer where you bought heater. Lower Shell Motor and Pump Assembly...
HIGH PRESSURE PORTABLE FORCED AIR HEATER 350,000 AND 600,000 BTU/HR THEORY OF FUELS VENTILATION OPERATION WARNING: Use only kero- WARNING: Follow the mini- The Fuel System: The motor turns the fuel sene or No. 1 fuel oil to avoid risk mum fresh, outside air ventila- pump.
OWNER’S MANUAL OPERATION TO RESTART HEATER Note: A cold heater may affect the thermo- stat setting. This thermostat is a general- heating control. It is not intended for precise CAUTION: Do not restart WARNING: Review and un- temperature control. Adjust thermostat un- heater until purge cycle is derstand the warnings in the til heater cycles at the desired setting.
HIGH PRESSURE PORTABLE FORCED AIR HEATER 350,000 AND 600,000 BTU/HR PREVENTATIVE WARNING: Never service MAINTENANCE heater while it is plugged in, op- erating, or hot. Severe burns and SCHEDULE electrical shock can occur. Item How Often How To Fuel tank Flush every 150-200 hours of operation or See Storing, Transporting, or Shipping, as needed...
OWNER’S MANUAL TROUBLESHOOTING WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. Only a qualified service person should service and repair heater. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Motor does not start when heater is plugged 1.
Page 8
HIGH PRESSURE PORTABLE FORCED AIR HEATER 350,000 AND 600,000 BTU/HR TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Heater will not ignite, but motor runs for a 1. A) Fuel tank empty 1. A) Add fuel to tank short period of time B) Water in fuel B) Check fuel tank for bubbles of C) Wrong fuel...
Page 9
OWNER’S MANUAL TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Heater ignites, but flame-out control shuts 1. Wrong pump pressure 1. Adjust pump pressure (see Pump Pres- off heater after a short period of time sure Adjustment, page 11) 2. Dirty fuel filters 2.
HIGH PRESSURE PORTABLE FORCED AIR HEATER 350,000 AND 600,000 BTU/HR SERVICE NOZZLE Air Deflector Remove upper shell (see column 1). PROCEDURES Remove fuel line from solenoid valve using 7/16" wrench. WARNING: Never service Remove spark plug wire from spark heater while it is plugged in, op- plug.
Page 11
OWNER’S MANUAL SERVICE PUMP (Procedure if Pump is Binding) PROCEDURES Remove upper shell (see page 10). Continued Loosen hex screw on flange clamp at rear of motor with 5/16" nut-driver Nozzle (see Figure 11). Plug Spark Turn fan with hand (see Figure 12). Plug If fan turns freely, tighten screw on flange clamp.
Page 12
HIGH PRESSURE PORTABLE FORCED AIR HEATER 350,000 AND 600,000 BTU/HR SERVICE FUEL FILTERS B. Pump Fuel Filter Unscrew canister bottom from canis- PROCEDURES A. Tank Fuel Filter ter top with adjustable pliers. Continued Disconnect fuel lines from pump and Remove fuel filter and gasket from can- pump fuel filter assembly with 7/16"...
OWNER’S MANUAL PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. 350,000 BTU/HR REF.
Page 16
HIGH PRESSURE PORTABLE FORCED AIR HEATER 350,000 AND 600,000 BTU/HR ILLUSTRATED PARTS BREAKDOWN 600,000 BTU/HR 105850...
Page 17
OWNER’S MANUAL PARTS LIST REF. PART NO. DESCRIPTION QTY. 600,000 BTU/HR 130-21889 Upper Shell 130-20805 Screw, #10-16 x 1/2" This list contains replaceable parts used in 130-21890 Combustion chamber & shield your heater. When ordering parts, be sure to 130-20931 Bushing provide the correct model and serial num- 130-21891...
Page 18
HIGH PRESSURE PORTABLE FORCED AIR HEATER 350,000 AND 600,000 BTU/HR Burner Head Assembly 350,000 and 600,000 Btu/Hr PART NO. DESCRIPTION QTY. 130-20808 Screw, #6-32 x 3/8" 130-20826 Photocell bracket 130-20830 Spark plug 130-20767 Nozzle (350,000 Btu/Hr) 130-21911 Nozzle (600,000 Btu/Hr) 130-20839 Plug 130-20836...
Page 20
Fax: 608 783-6115 I. WARRANTY A. Equipment B. Parts L.B. White Co., Inc. warrants that the component L. B. White Co., Inc. warrants that replacement parts of its equipment are free from defects in parts purchased from the company and used on material and workmanship, when properly the appropriate L.