(2) Available devices
The following table
(a) When 4E frame or QnA-compatible 3E frame is used
Classification
Input
Output
Internal relay
Latch relay
Annunciator
Edge relay
Link relay
Data register
Link register
Timer
Internal user device
Retentive
timer
Counter
Link special relay
Link special register
Step relay
Direct input
Direct output
Function input
Function output
Function register
Internal system device
Special relay
Special register
Index register
File register
Extended data register
Extended link register
*1
This is a code specified in MC protocol messages. When communicating data in ASCII code, specify the code in two
characters. If the code consists of only one character, add "*" (ASCII code: 2A
character.
*2
Devices of DX/DY1000 or later are not available. Use X/Y devices to access devices of X/Y1000 or later.
56
lists the devices available in the commands used for MC protocol communication.
Device code
Device
ASCII
X*
Y*
M*
L*
F*
V*
B*
D*
W*
Contact
TS
Coil
TC
Current value
TN
Contact
SS
Coil
SC
Current value
SN
Contact
CS
Coil
CC
Current value
CN
SB
SW
S*
*2
DX
*2
DY
-
-
-
SM
SD
Z*
R*
ZR
D*
W*
*1
Binary
9C
H
The number range of a device in a CPU module,
which is accessed to, can be specified.
9D
H
90
H
92
H
93
H
94
H
A0
H
A8
H
B4
H
C1
H
C0
H
C2
H
The number range of a device in a CPU module,
C7
which is accessed to, can be specified.
H
Note that the access to a local device is not possible.
C6
H
C8
H
C4
H
C3
H
C5
H
A1
H
B5
H
98
H
A2
H
A3
H
-
-
Cannot be accessed.
-
91
H
The number range of a device in a CPU module,
A9
which is accessed to, can be specified.
H
Note that the access to a local device is not possible.
CC
H
AF
H
The number range of a device in a CPU module,
which is accessed to, can be specified.
B0
H
• Binary: Within the device number range of the
A8
CPU module accessed
H
• ASCII: 000000 to 999999 (up to 976.6K points)
The number range of a device in a CPU module,
B4
H
which is accessed to, can be specified.
Device number range
) or a space (ASCII code: 20
H
Hexadecimal
Hexadecimal
Decimal
Decimal
Decimal
Decimal
Hexadecimal
Decimal
Hexadecimal
Decimal
Decimal
Decimal
Hexadecimal
Hexadecimal
Decimal
Hexadecimal
Hexadecimal
Hexadecimal
Hexadecimal
Decimal
Decimal
Decimal
Decimal
Decimal
Decimal
Decimal
Hexadecimal
) after the
H

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents