Mitsubishi Electric Q03UDVCPU User Manual page 137

Qnucpu series (communication via built-in ethernet port)
Hide thumbs Also See for Q03UDVCPU:
Table of Contents

Advertisement

(5) Program example
When M4000 is turned on, the receive data length of connection No.1 is read out.
• Devices used
Device number
SD1282
SD1286
D400
D4000
K1
• Program
CHAPTER 7 SOCKET COMMUNICATION FUNCTION
Application
Open completion signal
Receive state signal
S.SOCRDATA instruction control data
Storage location where data are read out
Number of read data (one word)
Reading receive data
length of Connection
No.1
135
7

Hide quick links: