KEYES ROSTOK Manual And Manual page 99

Table of Contents

Advertisement

Example: M241
Echoing may be controlled in some firmwares with M111
M245: Start cooler
Example: M245
used to cool parts/heated-bed down after printing for easy remove of the parts after print
M246: Stop cooler
Example: M246
M300: Play beep sound
Usage: M300 S<frequency Hz> P<duration ms>
Example: M300 S300 P1000
Play beep sound, use to notify important events like the end of printing.
on
R2C2
electronics.
M301: Set PID parameters - Hot End
Example: M301 P1 I2 D3 C5
Sets Proportional, Integral and
Derivative values for hot end, the value C refers to an extrusion rate.
Alternate implementation
Example: M301 W125
M303: Run PID tuning
Hotend Usage: M303
S<temperature> C<cycles> Bed Usage: M303 E-1 C<cycles> S<temperature> Example: M303
C8 S175
Generate Proportional, Integral and Derivative values for the hotend or bed (E-1). Send the
appropriate code and wait for the output to update the firmware.
M304: Set PID parameters - Bed
FiveD
Support
FiveD Teacup Sprinter Marlin
Support
FiveD
Teacup Sprinter
Support
97
See working example
Teacup Sprinter Marlin
PID
Repetier
PID
PID
Marlin
PID
Repetier
Repetier

Advertisement

Table of Contents
loading

Table of Contents