Example: M130 P 0 S 24 # Sets heater 0 D factor to 24.0
M133: Set PID I limit value
Example: M130 P 1 S 264 # Sets
heater 0 I limit value to 264
M134: Write PID values to
EEPROM
Example: M134
M136: Print PID settings to
host
Example: M136 P1 # print
heater 0 PID parameters to
host
M140: Bed Temperature (Fast)
Example: M140 S55
Set the temperature of the build
bed to 55
o
C and return control to
the host immediately (i.e. before
that temperature has been reached by the bed).
M141: Chamber Temperature (Fast)
Example: M141 S30
Set the temperature of the chamber to 30
that temperature has been reached by the chamber).
M142: Holding Pressure
Example: M142 S1
Set the holding pressure of the bed to 1 bar.
The holding pressure is in bar. For hardware which only has on/off holding, when the holding
pressure is zero, turn off holding, when the holding pressure is greater than zero, turn on holding.
M143: Maximum hot-end temperature
Example: M143 S275
Set the maximum temperature of the hot-end to 275C
FiveD
Teacup Sprinter Marlin
Support
yes
FiveD
Teacup Sprinter Marlin Repetier
Support
yes
FiveD
Teacup Sprinter Marlin
Support
Debug
FiveD
Teacup Sprinter Marlin Repetier
Support
yes
o
C and return control to the host immediately (i.e. before
93
Repetier
Repetier
yes
yes
yes

Advertisement

Table of Contents
loading