Reference; Specifications - Omron POWLI Instruction Manual

Table of Contents

Advertisement

Reference

A. Specifications
Type
Method
Operation method
Connectable devices
Input
Rated input voltage
Input voltage range
Frequency
Maximum current
Phase
Input plug shape
Input protection
Input protection capacity
Output
Allowable connection capacity *1
Voltage (effective value) *2
Peak voltage value
(In Commercial Power Mode)
Peak voltage value
(In Battery Mode)
Frequency
Phase
Output waveform
Waveform distortion rate
(Rectified load, at rated output)
Number of output receptacles
Power failure switching time
Commercial direct shipment (switching time)
Backup time *3
Battery
Type
Sealed lead battery life expectancy 4 to 5 years (long operating life) *At ambient temperature of 20˚C
Battery capacity (V/Ah) (x Quantity)
Charging time
Environment
Operating ambient temperature
Operating ambient humidity
Dimensions (W×H×Dmm)
Weight of unit
Internal power consumption (max.)
Noise regulation (compliance standard)
Safety standards / RoHS directive compliance
Noise
Serial communication (RS-232C)(Interface)
Serial communication (USB)(Interface)
Contact signal (Interface)
*1: Make sure that both the VA value and the W value of the load capacity connected to the UPS are within the range specified here.
*2: Check the operation beforehand if the unit is used in any mode other than "220V AC mode". In some cases, the maximum voltage
of output in Battery Mode may be lower than the maximum voltage in usual operation (commercial power supply).
*3: The backup times shown here are for when rated load is connected, at 20°C, and for initial characteristics.
*4: When an additional battery unit is connected, the charging time is 24 hours.
*5: The height includes the 13mm height of the rubber feet.
*6: The height includes the 56mm height of the casters.
*7: 170W max when and additional battery unit is connected.
*8: USB or RS-232C either is available. (unusable at the same time)
*9: This UPS is equipped with SC07 (NPN signal output card) at the time of factory shipment. To use the PNP connection, replace the
SC07 with the SC08G included in the package.
BU1002SWG
Full-time inverter supply method
PC, display, and peripherals
220/230/240 VAC
AC185±4 to 276±4V (with 85% or less connection load)
AC210±4 to 276±4V (with 85% or more connection load)
50/60Hz ± 4Hz
5.8A
Single-phase, two-wire
Schuko CEE 7/7P
Reset-type overcurrent protection device
10A
1000VA/700W
220V mode
230V mode
240V mode
220V mode: AC310V ± 6%
230V mode: AC324V ± 6% 240V mode: AC338V ± 6%
220V mode: AC310V+6%/-10%
230V mode: AC324V+6%/-10% 240V mode: AC338V+6%/-12%
50/60Hz ± 1Hz
Single-phase, two-wire
Sine wave
220V mode: 10% max.
230V mode: 10% max. 240V mode: 12% max.
IEC60320 C13: 3 pcs.
Terminal block: 2 lines
Uninterrupted
4msec. max.
Minimum 5 minutes
Compact sealed lead battery
12V DC/ 7.2 Ah (x 3)
8 hours *4
0 to 40˚C (during operation)/ -15 to 50˚C (during storage)
25 to 85%RH (during use)/10 to 90%RH (during storage)
145 x 395 x 224 (±1) mm *5
Approx. 15.5 kg
50W (100W max.)
VCCI Class A
CE / RoHS compliance
50 dB max.
D-Sub 9pin
B type*8
D-Sub 9pin*9
BU3002SWG
16A
Schuko CEE 7/7P
20A
3000VA/2100W
AC220V ± 3%
AC230V ± 3%
AC240V ± 3%
IEC60320 C19: 1 pcs. C13 : 5 pcs.
Terminal block: 2 lines
12V DC/ 8 Ah (x 6)
213 x 537 x 432 (±1) mm *6
Approx. 35 kg
55W (155W max.) *7
55 dB max.