6
. Maintenance and Inspection
3.
Turn the 2 screws that fix the plate cover counterclockwise to remove them. ➀
Pull the plate cover towards you ➁ and lift it up to remove it. ➂
1
4.
Hold the pullout label at the bottom of the battery pack and remove the battery pack.
Do not hold the connector or cable of the battery pack.
Use the red tape on the top of the battery pack, which is 10 cm from the inner edge of the battery, to
gauge how much further you need to pull the battery to remove it. Hold the battery securely with both
hands so as not to drop it.
48
Remove the 2 screws.
2
3
Red tape
Battery connector
Battery pack
Pullout label
(Pull this to remove.)