Installation and Reference Manual
Server section on page 252. Please then refer to the Using Telnet section from page 270 for further
details.
The files that are likely to be requested are:
Admin_xxxx.log – Call set up trace
Gateway_xxxx.log – ISDN trace
Voicemail_xxxx.log – voicemail trace
Core.xxxx – trace dumps
These files can be found in the root and should be copied to the ftp directory using the following
command:
mv a b
= move a to b
Once placed in the ftp directory these files can be accessed as described in the Admin Access to a Call
Server section on page 252.
You may also be asked to access the following files:
cat /dev/emlog0
cat /dev/emlog1
cat /dev/emlog2
cat /dev/emlog3

Using Setnet

Setnet is a facility that can be used to change the network configuration of a module, such as a Phone
Module, or PCS 580, 570, 560, 410, 400 or 100. Typical use would be to give a Phone Module or PCS IP
phone a static IP address.
Setnet is accessed as follows:
1
Within a Command prompt enter
telnet <ip address of Phone Module/PCS 580/570/560/410/400/100>
then press Enter
2
You will be prompted for a Username, enter
Maintenance & Troubleshooting
Installation and Reference Manual v3.2/0410/6
eg mv Admin_1265.log /ftp
catalogue file – this is main unit trace
gateway trace
voicemail trace
phone module trace
diag
, then press Enter
eg telnet 192.168.0.250