5. Specification

5.1 Power supply specification
Item
Power supply
Allowance power
failure time
Power consumption
5.2 General specifications
Item
Ambient temperature
Surrounding humidity
Vibration resistance
Shock resistance
Noise immunity
Dielectric withstand
voltage
Insulation resistance
Ground
Use atmosphere
5.3 Performance specification
Item
Number of control
axes
Application PLC
Program memory
Battery
Positioning unit
Accumulation
address
Speed instruction
Zero return
Absolute position
detection
Control inputs
Control outputs
DC24V -15%, +10%
The operation is continued to the momentary power failure is 5ms or less.
5W
0 to 55 °C (operation). -20 to 70 °C (storage).
35 to 85%,No condensation (operation). 35 to 90% (storage).
Conforms to JIS C0040. 10 to 57Hz: Half 0.035mm amplitude,
Sweep count for X,Y,Z: 10 times (80 min in each direction).
Conforms to JIS C0041. 147m/s
3 times in each direction X, Y, Z.
1,000Vp-p,1µs. 30 to 100Hz, tested by noise simulator.
500V AC > 1 min, tested between all points, terminal and ground.
5MΩ > 500V DC, tested between all points, terminal and ground
Class 3 (100Ω or less)
Ambient conditions to be free of corrosive gases. Dust should be minimal.
One axes
Bus connection with FX
occupied is 8 points. An FX
the FX
series PLC.
2NC
3.8 K steps. With built-in RAM
With built-in FX
-32BL type lithium battery.
2NC
Longevity and about 3 years (The guaranteed term is 1 year).
Command units: mm, deg, inch, pls, (relativity/absolutely)
Max command value ± 999,999 (32 bits when indirectly specifying)
-2,147,483,648 to 2,147,483,647 pulses
200kHz max., 153,000cm/min (200kHz or less). Automatic trapezoidal pattern
acceleration/deceleration
Manual operation or automatic operation. The DOG type machine zero return
(The DOG search function is provided). An automatic electric zero return is
possible by the electric starting point setting.
The absolute position detection is possible with MR-J2 and the MR-H type
servo motor with the ABS detection function.
Operation system: FWD (manual forwarding), RVS (manual reversal)
ZRN (machine zero return), START (automatic start), STOP,
Manual pulse generator (2kHz max), Single-step operation input
(Depends upon the parameter setting).
Mechanical system: DOG (near-point signal),
LSF (forward rotation limit), LSR (reverse rotation limit),
Interrupt: 4 points
Servo system: SVRDY(servo ready), SVEND (servo end),
PG0 (zero-point signal)
General purpose: The main body has X0 to X3.
Servo system: FP (forward rotation pulse). RP (reverse rotation pulse),
CLR (counter clear).
General purpose: The main body has Y0 to Y5.
Contents
Contents
57 to 150Hz: 4.9 m/s
2
acceleration, Action time: 11ms.
Contents
and the FX
series PLC. The number of I/O points
2N
2NC
-CNV-IF is necessary for the connection with
2NC