3.6 Inspect Cassette/Color Sensor Switch Mode ([3] key):
Required on the Production Line
Use 24 mm laminate black ink ribbon tape.
Be sure to provide power supply of DC12.0V ±0.1V / DC9.0V ±0.1V [Insert resistant
1Ω ±5% (2W and more)] for the inspection from DC power or AA battery.
Press the key below at the state of
<Figure
3.6-1>.
For European/North American models: [OK], [ENTER] or [3]
Procedures for "Inspect Cassette Sensor Switch Mode"
- Check the operation of 6 sensors by pressing the sensor switches (cassette
sensor (1) to (5).
- Press the sensor switches in the order of cassette sensor (1), (2), (3), (4), (5).
- Press one sensor at a time. If multiple sensors are pressed simultaneously, the
judge will be NG.
- The pressing order of the cassette sensor is as shown below.
(The numbers assigned to cassette sensor switch are different from ones
shown in "hard/soft connection specification".)
<Order of pressing cassette sensor>
Locking boss
- Pressing the key below during the inspection
7>) returns display to
For European/North American models: [OK] or [ENTER]
<Figure
3.5-1>, and the LCD displays as shown in
CASSETTE
Figure 3.6-1
(2)
(4)
(3)
(1)
(5)
<Figure
3.6-5>.
III - 26
Cassette sensor layout drawing
(<Figure
3.6-2> to
<Figure 3.6-