Mark
a)
Model
b)
SEC class
c)
c1)
SEC warm climates
SEC average climates
c2)
SEC cold climates
c3)
Energy label
Unit typology
d)
e)
Type of drive
Type of Heat Recovery System
f)
Thermal efficiency of heat recovery
g)
Maximum flow rate
h)
Electric power input at maximum flow rate
i)
j)
Sound power level (L
)
WA
Reference flow rate
k)
Reference pressure difference
l)
Specific power input (SPI)
m)
Control factor
n1)
Control typology
n2)
Maximum internal leakage rate
o1)
o2)
Maximum external leakage rate
Internal mixing rate
p1)
External mixing rate
p2)
Visual filter warning
q)
Instructions to install regulated grilles
r)
Internet address for pre/disassembly instructions
s)
Airflow sensitivity to pressure variations
t)
Indoor/outdoor air tightness
u)
AEC - Annual electricity consumption - warm climates
v1)
AEC - Annual electricity consumption - average climates
v2)
AEC - Annual electricity consumption - cold climates
v3)
w1)
AHS - Annual heating saved - warm climates
AHS - Annual heating saved - average climates
w2)
AHS - Annual heating saved - cold climates
w3)
20
ErP Directive - regulations 1253/2014 - 1254/2014
-
-
-
A
kWh/m2.a
-15
kWh/m2.a
-39,4
kWh/m2.a
-77,4
-
-
-
-
%
m3/h
W
dBA
m3/h
Pa
W/m3/h
-
0,65
Local
-
demand control
%
%
%
%
-
-
-
%
m3/h
kWh
2,2
kWh
2,6
kWh
8
kWh
20,5
kWh
45,3
kWh
88,7
AERAULIQA
QR550ABP
A
-10,7
-34,4
-71,3
Yes
Residential - bidirectional
Variable speed drive
Heat recovery
82
520
333
58
364
50
0,412
0,85
Central
demand control
control (no DCV)
0,8
0,5
N/A
N/A
Visual filter warning on display
N/A
www.aerauliqa.com
N/A
N/A
3,7
4,2
9,6
20
44,2
86,5
B
-6,7
-30
-66,1
1
Manual
5,2
5,6
11
19,6
43,4
84,8