Cleaning and maintenance
40
7.8

Instructions for replacing the lamps

The lamp effect decreases once 1000 hours have passed. As such, the re-
placement intervals specified in the maintenance plan must be adhered to.
WARNING!
Danger of being burnt by an over-powered lamp!
If the old chip card is left in the device, the new lamp set will
be run at too high power and the user may suffer heavy
burns!
The enclosed chip card must always be used when
changing the UV low pressure lamps!
7.8.1

Changing the chip card

The chip card belongs to the Beauty Light lamps and UV lamps.
The chip card is located in the 'Part support control'.
Opening the bed base: see page 39.
Remove the chip card belonging to the old lamp set.
Insert the new chip card with the arrow pointing downwards.
Close the bed base. You should hear the bed base click into place.