Screw the M8 connector of the hose with the red stripe into the
hole H.
Screw the M8 connector of the 800 mm hose into the hole B.
WD 3020/ WD 3030/ WD 3040
C
B
H
(fi g. 7)
Ensure the connections are screwed tight, but avoid over-
!
tightening.
Then put the base or O-Ring (3) over the hole and fi x the BRITA Tap
(1) in place using the supplied joint (5), the fl at gasket (6), fl ange (7)
and the brass nut (8).
3.4
Step 4: Attaching the hoses and additional
parts
We recommend that you fi rst arrange all parts you need in front of
you.
Recommended tools for installation: sealing tape, one Allen key
and an adjustable spanner wrench.
Recommended for installation of the wall mount bracket: two
screws (e.g. 5 mm in size suited to the mounting surface) and two
wall plugs (if necessary).
Please follow the diagram below (see fi g. 8) and perform the steps
in the right order.
A For this step please use the parts showed in fi g.1.
a) Wrap the sealing tape around the 1/4" thread of adapter (14) and
screw it into the pressure limiting valve (10). Screw the pressure
limiting valve on the 1/2" angle valve.
b) Insert a 1/2" fl at gasket into the hex nut of the T-piece (11) and
screw it on the assembled pressure limiting valve.
c) Place a 1/2" fl at gasket in the brass nut 1/2" of the hose (8) and
connect this hose with the T-piece (11).
d) Insert a 3/8" fl at gasket into the other side of the hose and
screw this hose to the side of the fi lter head inlet, which is
labeled "IN".
If you do not have an isolating valve, please use the isolating
!
valve (13) included in the kit.
8
ENGLISH
1014663-001_GA_BRITA_Tap_AU.indb 8
1014663-001_GA_BRITA_Tap_AU.indb 8
If you do have an additional free 1/2" cold water supply for
!
the BRITA Tap in your kitchen, you do not need to install the
supplied T-piece.
B Connect the hose with the blue stripe to one side of the T-piece
(or free 1/2" cold water supply). Please make sure that pre-
assembled gasket is placed right.
C Connect the 800 mm hose to the "OUT" (connection point on
fi lter head) which labelled with an "OUT" arrow. Please make
sure that pre-assembled gasket is placed right.
D Connect the hose with the red stripe with your hot water supply.
Please make sure that pre-assembled gasket is placed right.
E Make sure all connections are tightened properly. Avoid over
tightening.
Hot water
(fi g. 8)
supply
Cold water
supply
The max. tightening torque for the G 3/8" connections may
not exceed 14 Nm! Only hose connections with washers
!
may be used – hoses with conical screw connections dam-
age the connections of the fi lter head and invalidate any
warranty claims.
(Optional,
if shutoff is
required)
28.04.15 15:25