6.

Architectural Drawings

6.1

Example of Cavity Design - Section View

12mm 'Micore' board*
12mm 'Micore' board*
NOTES
1. Angle section for support fi xed to timber frame/fl oor using coach screws or 'Dynabolts' when fi xing to concrete.
2. The joint for fi re rated board* and Plasterboard located over frame member must be stopped to manufacturer's
instructions. Note: Wallpaper is not permitted on the front of the enclosure.
3. Comply with all minimum distance to all combustible surfaces. Any modifi cations to the dimensions shown to
be verifi ed by consultation with the relevant Building Consent Authority.
4. Ensure there is a minimum of 100cm
5. Installers must ensure adequate vermin proof measures are incorporated into the cavity construction (if
applicable).
*Ensure product being used is fi reproof rated above 80°C eg Micore, Supalux, Eterpan or similar
Page 5
~200mm
ventilation into the cavity (this does not need to be from the outside).