7.1

Explanation of Alarms

DISPLAY
MAGNA CAMPO
or
CERCA CAMPO
WARNING
PELLETS FINISHED
ALARM
BLACK - OUT
NO IGNITION ALARM
LOW FLAME ALARM
FAN RPM ALARM
FAN BROKEN ALARM
DEPRESSION ALARM
THERMAL ALARM WITH
RESET
HOT SMOKE ALARM
SMOKE SENSOR ALARM
AUGER BLOCKED
ALARM
12
REASON
Sara/Camino
is not responding
to remote
REASON
• The pellet hopper is empty
• The raio-motor does not load
pellets.
• Pellets not loading.
• No electricity supply during
working phase.
• The pellet hopper is empty
• Setting of pellets and of intake
during ignition phase insufficient
• The ignitor is defective
• The pellet hopper is empty
• Bad setting of pellet and air
during ignition
• The revolution of smoke fan
lowering more than 15% of speed
to fan congestion
• Smoke extractor encoder is
not functioning or not correctly
connected
• No electricity supply to smoke
extractor
• The smoke extractor is blocked
• The combustion chamber is dirty
• The flue is blocked
• The vacuum switch is
malfunctioning
• The thermostat with manual reset
has intervened
• The centrifugal fan is defective
• Combustion in the fire pot is not
optimal
• Combustion in the fire pot is not
optimal
• The centrifugal fan is defective
• The smoke sensor is
malfunctioning
• The smoke sensor has been
disconnected from the board
• The auger does not load pellets
SOLUTION
- Check
fire is fully pushed into position
- Check Batteries in Remote
-
Check
remote
is syncronised
-
Check
power supply
to fire is
SOLUTION
• Check whether there are pellets in the hopper and refill if
necessary.
• Empty the hopper to check that no foreign objects have fallen
inside which could prevent the correct functioning of the
auger.
• Contact local Service Technician
• IF THE PROBLEM CONTINUES, CONTACT YOUR LOCAL
SERVICE TECHNICIAN.
• Press the off button and repeat switching on the stove.
• IF THE PROBLEM CONTINUES, CONTACT YOUR LOCAL
SERVICE TECHNICIAN.
• Check whether there are pellets in the hopper and refill if
necessary.
• Contact local Service Technician.
• Contact local Service Technician.
• Check whether there are pellets in the hopper and refill if
necessary.
• Contact local Service Technician.
• Contact local Service Technician.
• Contact local Service Technician.
• Contact local Service Technician.
• Contact local Service Technician.
• Follow the cleaning operations of the stove as per the
instructions manual.
• Check that the flue is clear and clean.
• Contact local Service Technician.
• Reset the thermostat pressing the button on the back of the
stove.
• Contact local Service Technician.
• Switch off the stove, clean the fire pot and regulate
combustion with the setting of the pellets.
• Switch off the stove, clean the fire pot and regulate
combustion with the setting of the pellets.
• Contact local Service Technician.
• IF THE PROBLEM CONTINUES, CONTACT YOUR LOCAL
SERVICE TECHNICIAN.
• Contact local Service Technician.
• Contact local Service Technician.
• Contact local Service Technician.