Page 1
Camino Wood Pellet Fire Owner’s & Installation Manual PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD PELLET FIRE. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
Page 2
If you are a not a registered pellet re installer, and do not have legitimate access to the necessary passwords to install and program the Camino Wood Pellet re, you MUST NOT install or attempt to install this e.
ecti n Contents Maintenance and Cleaning .......13 Burn Pot Liner (daily) ..........13 Introduction ............2 Heat Exchanger Tubes (daily) ....... 14 c i f . . s ....
1.1.1 Rating label Location Pellet Quality each lighting Ravelli Camino: The rating label is located on the back of unit. Pellet quality is important - please read the following: You must check that the Burn Pot Liner, where the 1.1.2...
of replacement parts not supplied by the manufacturer is prohibited. Safety Warnings & Maintenance Recommendations Pellet Quality each lighting Pellet quality is important - please read the following: You must check that the Burn Pot Liner, where the combustion takes place, is clean and that no waste or (6mm) diameter wood pellets, manufactured to the AS/ residue blocks the holes, in order to always guarantee NZS 4014.6 standard only.
They must always be protected from the is equal to about 650 kg/m. damp both during transport and in storage. Ravelli recommends using a pellet with a diameter of 6 mm for Due to the low content of water (approx 8%) they have a the stove.
Before you begin Responsibility o l l l l e n i l l l a i l i , y t l i v precautions: and criminal, with the delivery of this manual, for any accidents deriving from partial or total failure to observe •...
5.1.1 How to extract the stove: Open the stove’s door and extract the locking mechanism Ensure burn pot is clean and the burn pot holes are Brochure for FLAT - 900 model lever using the corresponding hook (SUPPLIED) shown visible. in the illustration.
locking mechanism is the locked position before closing reinstalled. the door. Switch the power to the fire off at the mains switch. Press the triangle keys 1 and 2 on the handset Important: Pushing the fire back in with the together for about 3 seconds.
Operating Instructions to the stove and the room in which it is installed. In any case, when a problem arises, the pellets stop falling The heater is completely automated and will self-regulate immediately and the switch off phase is activated. The corresponding alarm will be shown on the display.
day with [1] or [2] (24 hour clock) example: 4:30p.m 11. Repeat steps 4 through 10 to set program 2 (if would be 16:30 required) 12. Once you have completed setting up program 2 Press [3] to exit MINUTES CLOCK will appear on the display. Change the minutes of the day with buttons [1] or [2] Possible Settings Description...
Menu Five - Stove State (Fire Status) Note: DO NOT leave the remote down the side In this menu, you can check the correct functioning of of the sofa, on a window ledge or in a cold some of the key components of the pellet fire. draft, in another room, or in the flow of hot air coming off the fire.
then press and hold [6] for 3 seconds. The display Menu Six - Working Hours will show “SCREW STATE”. The WORKING HOURS Menu shows the total run hours Use Button [1] to turn the Auger On “SCREW 1” and button [2] to turn it OFF. Once started auger will run for a couple of minutes To enter this menu, proceed as follows: Remember to turn the screw OFF (SCREW 0) with...
Explanation of Alarms DISPLAY REASON SOLUTION - Check fire is fully pushed into position MAGNA CAMPO Sara/Camino is not responding - Check Batteries in Remote to remote Check remote is syncronised with fire CERCA CAMPO Check power supply to fire is...
Maintenance and Cleaning Before carrying out any maintenance take the following • Make sure that the plug is disconnected from the precautions: socket, thus avoiding accidental electric shocks. • Always use appropriate tools for maintenance. • Make sure that the general power supply has been disconnected.
RIGHT HAND SIDE FRONT Heat Exchanger Tubes (daily) All Ravelli products have a combustion chamber made The handle for the heat exchanger cleaning rod is pointed with FIREX 600, a material based on vermiculite, the out in the first image below. This handle is to be pulled result of research and development by Ravelli.
The door glass is made of special high temperature require special PYROCERAMIC. The use of substitute materials is maintenance, it only prohibited use only official Ravelli replacement parts has to be dusted with a brush to remove the Seal & Gaskets (monthly) ash that is deposited during combustion.
It 1.1. Dimensions Ravelli Camino) The data shown are indicative and not binding. Ravelli reserves the right to make any for the purpose of improving the performances of the product. Height 557mm Width...
& of manufacture. labour Auger Motor After installation, covered components Circuit Board, manufactured by Ravelli are found to be defective in decal & mounting materials or workmanship during the applicable warranty bracket period,Pellet Fire Solutions will, at its Blowers discretian , epair or replace the covered components.
The owner’s exclusive remedy and Pellet Fire guides, and the discolouration of glass. Solutions Ravelli's sole obligation under this warranty, under any other warranty, express or • Minor expansion, contraction, or movement of certain implied, or in contract, tort or otherwise, shall be parts causing noise.
11. Proof of Purchase/Warranty ....................... Date of Purchase: ....................... Amount Paid: $ ..................... Payment Method: o Credit Card o EFTPOS o Cash o Other Attach receipt and other documents here Page 19...
Solutions declines all responsibility. The data shown are indicative and not binding. Generally the Camino should be installed in a centrally Ravelli reserves the right to make any located position within the home. When deciding The fi re must be installed on a fl oor with suffi cient...
Solutions declines all responsibility. Generally the Camino should be installed in a centrally located position within the home. When deciding The fi re must be installed on a fl oor with suffi cient where to position the appliance, you must consider the carrying capacity.
ATTENTION There are two critical components when installing a Camino Insert Wood Pellet re: 1) Ensure the wall cavity is the necessary size. 2) Ensure relevant clearances to combustibles are adhered to both inside and outside the cavity.
In accordance with the requirements of AS/NZS • Poor maintenance. 2918:2001 Camino must be secured by seismic restraint. • Failure to observe the instructions in the manual. • Use not compliant with the safety instructions.
Creating the Cavity As the Camino Insert Wood Pellet Fire is typically Additional Clearances to Combustibles installed in new homes, it is necessary to build a compliant cavity that will house the re and (K): from exhaust spigot to cavity wall 110mm the frame.
Architectural Drawings Example of Cavity Design - Section View 12mm ‘Micore’ board* 12mm ‘Micore’ board* ~200mm NOTES 1. Angle section for support fi xed to timber frame/fl oor using coach screws or ‘Dynabolts’ when fi xing to concrete. 2. The joint for fi re rated board* and Plasterboard located over frame member must be stopped to manufacturer’s instructions.
(min size 90x45) shall be provided. Ventilation The Camino wood pellet fi re requires fresh air to function properly. Without suffi cient ventilation, the combustion process can be compromised, resulting in issues such as a lazy fl ame, smoke, incomplete fuel combustion, wasted fuel, excessive ash build-up and clinker.
Heat-resistant floor protector installer as per the manufacturer’s instruc- floor protector tions and AS/NZS2918:2001. NOTE: Camino must be installed on an approved, raised-stand, while Sara can be installed lower to the oor with an optional 45mm base. Page 8...
15. Flashing Options Decktite - For all Steel Roof Profi les Please circle the fl ashing option to be used. When considering an alternative method please consult your local council. 16. Controls and Menus 16.1 Description of Controls • P1 : Button to decrease general values •...
16.3 Menu Descriptions Press [7] to confi rm TIME CLOCK will appear on the display and the The fi re has various functions arranged in different current time will be shown. Change the hours of the menus. Some of these menus are accessible by the day with [1] or [2] (24 hour clock) example: 4:30p.m user, others are protected by a password and accessible would be 16:30...
Page 35
16.3.4 Menu Five - Stove State (Fire Status) The auger is activated In this menu, you can check the correct functioning of some of the key components of the pellet fi re. Exhaust Fan RPM Exhaust Temperature The auger is idle Auger Status 1 = ON 0 = OFF Stove Status...
fi from Pelle Fire Solutions 17.1 Camino Parameters - version BOX 03 Before After Adjusted Name Program Unit Value Programming Programming Settings...
Page 37
Degrees PR37 °C / °F °C Blackout PR38 Re-ignition block PR39 T-extinction min PR40 Fan 2 threshold PR41 °C Comfort climate PR42 on / off Fan 2 speed - 1 PR43 Fan 2 speed - 2 PR44 Fan 2 speed - 3 PR45 Fan 2 speed - 4 PR46...
PRODUCER REGISTRATION FORM This form must be completed and returned for every installation to qualify for warranty. Post to: P O Box 11-245, Sockburn, Christchurch Email to: info@pelletfiresolutions.co.nz Customer Details: Customer Name: Postal Address: Installation Address: Phone Number Cell Phone Email Address Declaration by Owner: I hereby certify the above particulars are true and correct.
Need help?
Do you have a question about the Camino and is the answer not in the manual?
Questions and answers