venting system should be inspected and cleaned at
least once every year or after every ton of pellets burnt.
We recommend contacting your dealer for professional
cleaning. To remove dust from the vent pipe, tap lightly
on the pipe to dislodge any loose ash. Open the bottom
of the
adapter box and vacuum as much of the ash
out of the vent pipe as possible.
8.10

Blower Mechanisms (yearly)

Pull the
forward to access the two blowers. Vacuum
all dust from motors and convection fan blades. DO
NOT lubricate these fans they have sealed bearings.
8.11

Post season clean-up

Once you are
using the pellet appliance for the
season, unplug the
for added electrical protection. It
1.1. Dimensions Ravelli
Height
Width
Depth
Weight
Diameter of smoke exhaust
Min - Max
power
Min - max hourly consumption of pellets
Electrical power absorbed during operation
Supply
Hopper Capacity
Space Heating
16
(
Camino)
is very important that the
serviced as stated above. Exposed metal part may be
painted with high temperate paint to prevent rusting over
the off season.
8.12

Cleaning the surfaces

To clean the surfaces on the painted metal parts, use a
damp cloth.
Important: the use of aggressive detergents or
abrasive cleaners can damage the surfaces of the
stove.
The data shown are indicative and not binding.
Ravelli reserves the right to make any
for the purpose of improving the
performances of the product.
557mm
705mm
650mm
150kg
80mm
3.7Kw/h - 8.2Kw/h
0.8kg/h - 1.9kg/h
240W
220V - 50Hz
17kg
88%
be thoroughly cleaned and