FOR YOUR SAFETY, READ BEFORE INSTALLATION:
Do not install the heater where water, debris or
flammable vapors may get into the flue terminal.
This may cause damage to the heater and void the
warranty.
Prohibited
Do not install this water heater under an
overhang less than 3 ft (915 mm) from its top
or eaves. The area under an overhang must be
open to three sides. (Outdoor models only)
Water heater vent terminator must be at least 2
ft (610 mm) away from an inside corner for both
outdoor installation and direct-vent installation.
(610 mm)

WARNING FOR INSTALLATIONS

3 ft
(915 mm)
2 ft
Inside
Corner
11
Do not have the vent terminal pointing toward
any opening into a building. Do not locate your
heater in a pit or location where gas and water
can accumulate.
Prohibited
Ensure that you meet the minimum clearances
shown below for a direct vent termination:
USA: 1 ft (30 cm) min.
Canada: 3 ft (91 cm) min.
Anticipated snow level
Do not install next to a dryer or any source
of airborne debris that can be trapped inside
the combustion chamber, unless the system is
direct-vented.
Page
Installation Manual
Installation
USA: 1 ft (30 cm) min.
Canada: 3 ft (91 cm) min.
USA: 1 ft (30 cm) min.
Canada: 3 ft (91 cm) min.
USA: 12 in. (30 cm) above grade and
above anticipated snow level
Canada: 12 in. (30 cm) above grade