FOR YOUR SAFETY, READ BEFORE INSTALLATION:
Do not install the heater where water, debris or
flammable vapors may get into the flue terminal.
This may cause damage to the heater and void the
warranty.
Prohibited
Do not install this water heater under an
overhang less than 3 ft. from its top or eaves.
The area under an overhang must be open to
three sides (Outdoor models only).
Water heater vent terminator must be at least 2
ft. (610 mm) away from an inside corner for both
outdoor installation and direct-vent installation.
(610 mm)

WARNING FOR INSTALLATIONS

3 ft.
(915 mm)
2 ft.
Inside
Corner
9
Page
Installation Manual
Do not have the vent terminal pointing toward
any opening into a building. Do not locate your
heater in a pit or location where gas and water
can accumulate.
Prohibited
Do not install the water heater vent terminator
within 1 ft. in the USA of any air intake or building
opening, and within 3 ft. in Canada of any air
intake or building opening (Outdoor models
only, refer to p. 16).
1 ft. (305 mm) USA
3 ft. (914 mm) Canada
Do not install next to a dryer or any source
of airborne debris that can be trapped inside
the combustion chamber, unless the system is
direct-vented.
Installation
1 ft. (305 mm) USA
3 ft. (914 mm) Canada
1 ft. (305 mm) USA
3 ft. (914 mm) Canada