Electrical Connections; Temperature Remote Controller; Installation - Takagi 110 Outdoor Installation Manual And Owner's Manual

On-demand water heater
Hide thumbs Also See for 110 Outdoor:
Table of Contents

Advertisement

Ensure that circuit power is turned OFF before you complete the following steps.
Follow the electrical code requirements of the local authority having jurisdiction.
In the absence of such requirements, follow the current edition of the National
Electrical Code ANSI/NFPA 70 in the U.S. or the current edition of CSA C22.1 Canadian
Electrical Code Part 1 in Canada.
WARNING
When servicing or replacing parts within the water heater, label all wires prior to
disconnection to facilitate an easy and error-free reconnection. Wiring errors can
cause improper and dangerous operation. Verify proper operation after servicing.
Failure to observe these warnings could result in personal injury or loss of life.
All indoor models come with a power plug instead of a junction box. The following procedure is for
outdoor models only.
1. The water heater requires a 120 VAC, 60 Hz electrical power supply that is properly grounded. Do
not attach the ground wire to either the gas or the water piping.
• A proper disconnect (i.e. on/off switch, power plug, etc.) controlling the main power to the water
heater must be provided for service reasons. (Must comply with local codes.)
• Connect the power supply to the water heater exactly as shown in the wiring diagram.
2. A green screw is provided in the junction box to ground the connection.
3. Can be hardwired or wired to a plug-in.
4. The use of a surge protector is recommended in order to protect the unit from power surges.
Indoor models only

TEMPERATURE REMOTE CONTROLLER

• This remote controller is NOT waterproof.
• The water heater can only have one remote controller.
• Do not install in high temperature environments, high humidity conditions outdoors, in
direct sunlight, or within the reach of children.
WARNING
• Make sure the remote controller does not come into contact with water or oil.
Do not place the remote controller cable close to other wires from other products.
NOTICE
Cables used for the remote controller connection must be:
Minimum 20 gauge wire (No polarity)
100112183 (TK-RE02) 110 & 310 models: Maximum 150 ft (46 m) long
100112155 (TM-RE30) for 510 model: Maximum 400 ft (122 m) long
<Mounting and wiring the remote controller>
For detailed connection to the remote controller, refer to the instructions that are packaged
with the remote controller.
1. Disconnect power supply from the water heater.
2. Take off the water heater's front cover.
3. Choose a location where you can install the remote controller.
4. Cut the two-pair wire to the correct length.
5. Crimp on supplied fork connectors.

ELECTRICAL CONNECTIONS

Outdoor models only
Bottom view of water heater

-Installation-

27
Page
Installation Manual
Green screw
View of electrical connections of water heater
Installation
Connect
power supply
120VAC, 60Hz
Ground

Hide quick links: