FOR YOUR SAFETY, READ BEFORE INSTALLATION:
Do not install the heater where water, debris or
flammable vapors may get into the flue terminal.
This may cause damage to the heater and void the
warranty.
Prohibited
Do not install this water heater under an
overhang less than 3 ft. (914 mm) from its top
or eaves. The area under an overhang must be
open to three sides (Outdoor models only).
Water heater vent terminator must be at least 2
ft. (610 mm) away from an inside corner for both
outdoor installation, indoor single vent, or direct-
vent installation.
(610 mm)

WARNING FOR INSTALLATIONS

3 ft.
(914 mm)
2 ft.
Inside
Corner
11
Do not have the vent terminal pointing toward
any opening into a building. Do not locate your
water heater in a pit or location where gas and
water can accumulate.
Prohibited
Do not install the water heater direct vent ter-
minator within 1 ft. (30 cm) in the USA of any air
intake or building opening, and within 3 ft. (91
cm) in Canada of any air intake or building open-
ing ( Refer to pp. 24 and 25.).
1 ft. (30 cm) min. USA
3 ft. (91 cm) min. Canada
Anticipated snow level
Do not install next to a dryer or any source
of airborne debris that can be trapped inside
the combustion chamber, unless the system
is direct-vented. The air intake must maintain
a safe distance from the dryer's exhaust vent.
This will help to prevent lint from being drawn
into the water heater's air intake.
Page
Installation Manual
Installation
1 ft. (30 cm) min. USA
3 ft. (91 cm) min. Canada
1 ft. (30 cm) min. USA
3 ft. (91 cm) min. Canada
12-inches (30.48 cm) above grade
or anticipated snow level