-Features available only on 100112155 (TM-RE30)-
<Set the time>
1. Press the "TIME" button, then press the "HOT" or "COLD" button to set the clock time.
2. Press the "TIME" button again to save and exit.
NOTE: If you want to hide the clock time, press and hold the "TIME" button for 3 seconds or longer.
<Energy saving mode >
The remote controller has an energy saving mode. The backlight of the LCD in the remote controller will
be turned off in five minutes after the water heater stops the operation for energy saving. Once the unit
is working, the backlight of the LCD is turned back on during the operation.
<Unit conversion mode>
Units of measure can be changed from Imperial to Metric and vice versa. For example, temperature can
be changed from °F to °C. Flow rate will also change from gallons per minute to liters per minute when
this setting is changed. Follow this procedure to change this setting:
1. Turn off power to the remote controller by pressing the "ON/OFF" button.
(Lamp is OFF to indicate that power is off.)
2. Press and hold both the "HOT" and "COLD" buttons simultaneously for at least 5 seconds, then make
sure that "1" (or "0") is displayed on remote controller.
"1" is displayed for single unit.
3. Press the "TIME" button. Make sure that "OFF" and "F1" are displayed on remote controller.
4. Press the "HOT" button or "COLD" button to set display to "F3".
5. Press the "INFO" button. Afterward, make sure that "°F" blinks.
6. Press the "HOT" button or "COLD" button to set display to "°C".
7. Press both the "BUZZER" button and "INFO" button simultaneously to save the setting. Make sure that
the display is no longer blinking.
8. Press the "ON/OFF" button to exit the edit mode.
9. Turn on power to the remote controller by pressing the "ON/OFF" button again. (Lamp is ON to
indicate that power is on.)
NOTICE
For more details, refer to the manual that came with your remote controller.
L /M G /M
I
N
O UT
FLOW
"0" is displayed for Easy-Link System.
L/ M G/ M
I
N
O U T
FLOW
L/ M G/ M
I
N
O U T
FLOW
L/ M G/ M
I
N
O U T
FLOW
L/ M G/ M
I
N
O UT
FLOW
I
N
L/ M G/ M
OU T
FLOW
40
L/ M G/ M
I
N
O U T
FLOW
Blinking
Blinking
Stops blinking
Page
Owner's Guide
Normal Operation