Check the altitude where your water heater is installed. Set DIP switches shown in the table below. The
DIP switch settings depend on the altitude.
• Adjust the appropriate DIP switches according to model and elevation as
shown below. DO NOT adjust the other DIP switches.
• Turn off the power supply to the water heater before changing the DIP
WARNING
switch settings.
• Failure to observe these warnings could lead to carbon monoxide poisoning
or death.
The maximum certified or allowable installed altitude is 6,000 ft (1,829 m) for indoor and out-
door models.
110 and 310 models
Computer board
DIP switches
110 and 310 models
Altitude
Switch No. 3
Switch No. 4
510 model (Left bank of DIP switches)
Altitude
Switch No. 4
Switch No. 5
NOTE: The dark squares indicate the correct DIP switch positions.
HIGH-ALTITUDE INSTALLATIONS
Installation altitude
0 to 2,000 ft
(0 to 610 m)
DEFAULT
OFF
OFF
1
2
3
4
5
6
7
8
ON
0 to 2,000 ft
(0 to 610 m)
DEFAULT
OFF
OFF
1
2
3
4
5
6
ON
12
510 model
Computer board
DIP switches (Left bank)
2,000 to 4,000 ft
4,000 to 6,000 ft
(611 to 1,219 m)
(1,220 to 1,829 m)
ON
OFF
1
2
3
4
5
6
7
8
ON
ON
2,000 to 4,000 ft
4,000 to 6,000 ft
(611 to 1,219 m)
(1,220 to 1,829 m)
ON
OFF
1
2
3
4
5
6
ON
Page
Installation Manual
Installation
OFF
ON
1
2
3
4
5
6
7
8
OFF
ON
1
2
3
4
5
6
ON