Dr-## Data Readouts - GE AF-600 FP Operating Instructions Manual

Fan and pump drive 460v/575v 150hp and above
Hide thumbs Also See for AF-600 FP:
Table of Contents

Advertisement

How to Program

6.2.18 DR-## Data Readouts

Par. No. # Parameter description
DR-0#
DR-00
Control Word
DR-01
Reference [Unit]
DR-02
Reference [%]
DR-03
Status Word
DR-05
Main Actual Value [%]
DR-09
Custom Readout
DR-1#
6
6
DR-10
Power [kW]
DR-11
Power [hp]
DR-12
Motor Voltage
DR-13
Frequency
DR-14
Motor Current
DR-15
Frequency [%]
DR-16
Torque [Nm]
DR-17
Speed [RPM]
DR-18
Motor Thermal
DR-2#
DR-22
Torque [%]
DR-3#
DR-30
DC Link Voltage
DR-32
Brake Energy /s
DR-33
Brake Energy /2 min
DR-34
Heatsink Temp.
DR-35
Drive Thermal
DR-36
Drive Nominal Current
DR-37
Drive Max. Current
DR-38
Logic Controller State
DR-39
Control Card Temp.
DR-4#
DR-40
Trending Buffer Full
DR-43
Timed Actions Status
DR-49
Current Fault Source
DR-5#
DR-50
External Reference
DR-52
Feedback [Unit]
DR-53
Digi Pot Reference
DR-54
Feedback 1 [Unit]
DR-55
Feedback 2 [Unit]
DR-56
Feedback 3 [Unit]
DR-58
PID Output [%]
DR-6#
DR-60
Digital Input
DR-61
Terminal 53 Switch Setting
DR-62
Analog Input 53
DR-63
Terminal 54 Switch Setting
DR-64
Analog Input 54
DR-65
Analog Output 42 [mA]
100
AF-600 FP High Power Operating Instructions
Default value
0 N/A
0.000 ReferenceFeed-
backUnit
0.0 %
0 N/A
0.00 %
0.00 CustomReadoutUnit
0.00 kW
0.00 hp
0.0 V
0.0 Hz
0.00 A
0.00 %
0.0 Nm
0 RPM
0 %
0 %
0 V
0.000 kW
0.000 kW
0 °C
0 %
ExpressionLimit
ExpressionLimit
0 N/A
0 °C
[0] No
[0] Timed Actions Auto
0 N/A
0.0 N/A
0.000 ProcessCtrlUnit
0.00 N/A
0.000 ProcessCtrlUnit
0.000 ProcessCtrlUnit
0.000 ProcessCtrlUnit
0.0 %
0 N/A
[0] Current
0.000 N/A
[0] Current
0.000 N/A
0.000 N/A
4-set-up
Change
Conver-
during
sion
operation
index
All set-ups
FALSE
0
All set-ups
FALSE
-3
All set-ups
FALSE
-1
All set-ups
FALSE
All set-ups
FALSE
-2
All set-ups
FALSE
-2
All set-ups
FALSE
1
All set-ups
FALSE
-2
All set-ups
FALSE
-1
All set-ups
FALSE
-1
All set-ups
FALSE
-2
All set-ups
FALSE
-2
All set-ups
FALSE
-1
All set-ups
FALSE
67
All set-ups
FALSE
0
All set-ups
FALSE
0
All set-ups
FALSE
0
All set-ups
FALSE
0
All set-ups
FALSE
0
All set-ups
FALSE
100
All set-ups
FALSE
All set-ups
FALSE
-2
All set-ups
FALSE
-2
All set-ups
FALSE
All set-ups
FALSE
100
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
-1
All set-ups
FALSE
-3
All set-ups
FALSE
-2
All set-ups
FALSE
-3
All set-ups
FALSE
-3
All set-ups
FALSE
-3
All set-ups
TRUE
-1
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
-3
All set-ups
FALSE
All set-ups
FALSE
-3
All set-ups
FALSE
-3
Type
V2
Int32
Int16
0
V2
N2
Int32
Int32
Int32
Uint16
Uint16
Int32
N2
Int32
Int32
Uint8
Int16
Uint16
Uint32
Uint32
Uint8
0
Uint8
Uint32
Uint32
0
Uint8
Uint8
-
Uint8
-
Uint8
0
Uint8
Int16
Int32
Int16
Int32
Int32
Int32
Int16
0
Uint16
-
Uint8
Int32
-
Uint8
Int32
Int16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents