Ap-## Hvac Appl. Param - GE AF-600 FP Operating Instructions Manual

Fan and pump drive 460v/575v 150hp and above
Hide thumbs Also See for AF-600 FP:
Table of Contents

Advertisement

How to Program

6.2.20 AP-## HVAC Appl. Param.

Par. No. # Parameter description
AP-0#
AP-00
External Interlock Delay
AP-2#
AP-20
Low Power Auto Set-up
AP-21
Low Power Detection
AP-22
Low Speed Detection
AP-23
No-Flow Function
AP-24
No-Flow Delay
AP-26
Dry Pump Function
AP-27
Dry Pump Delay
AP-3#
AP-30
No-Flow Power
AP-31
Power Correction Factor
AP-32
Low Speed [RPM]
AP-33
Low Speed [Hz]
AP-34
Low Speed Power [kW]
AP-35
Low Speed Power [HP]
AP-36
High Speed [RPM]
AP-37
High Speed [Hz]
AP-38
High Speed Power [kW]
AP-39
High Speed Power [HP]
AP-4#
AP-40
Minimum Run Time
AP-41
Minimum Sleep Time
AP-42
Wake-up Speed [RPM]
AP-43
Wake-up Speed [Hz]
AP-44
Wake-up Ref./FB Difference
AP-45
Setpoint Boost
AP-46
Maximum Boost Time
AP-5#
AP-50
End of Curve Function
AP-51
End of Curve Delay
AP-6#
AP-60
Broken Belt Function
AP-61
Broken Belt Torque
AP-62
Broken Belt Delay
AP-7#
AP-70
Compressor Start Max Speed [RPM]
AP-71
Compressor Start Max Speed [Hz]
AP-72
Compressor Start Max Time to Trip
AP-73
Starting Acceleration Time
AP-75
Short Cycle Protection
AP-76
Interval between Starts
AP-77
Minimum Run Time
AP-8#
AP-80
Flow Compensation
AP-81
Square-linear Curve Approximation
AP-82
Work Point Calculation
AP-83
Speed at No-Flow [RPM]
AF-600 FP High Power Operating Instructions
Default value
0 s
[0] Off
[0] Disabled
[0] Disabled
[0] Off
10 s
[0] Off
10 s
0.00 kW
100 %
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
10 s
10 s
ExpressionLimit
ExpressionLimit
10 %
0 %
60 s
[0] Off
10 s
[0] Off
10 %
10 s
ExpressionLimit
ExpressionLimit
5.0 s
ExpressionLimit
[0] Disabled
ExpressionLimit
0 s
[0] Disabled
100 %
[0] Disabled
ExpressionLimit
4-set-up
Change
Conver-
during
sion
operation
index
All set-ups
TRUE
0
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
0
All set-ups
TRUE
All set-ups
TRUE
0
All set-ups
TRUE
1
All set-ups
TRUE
0
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
1
All set-ups
TRUE
-2
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
1
All set-ups
TRUE
-2
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
All set-ups
TRUE
0
All set-ups
TRUE
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
-1
2 set-ups
TRUE
-2
All set-ups
TRUE
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
All set-ups
TRUE
0
All set-ups
TRUE
All set-ups
TRUE
67
Type
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
Uint16
-
Uint8
6
6
Uint16
Uint32
Uint16
Uint16
Uint16
Uint32
Uint32
Uint16
Uint16
Uint32
Uint32
Uint16
Uint16
Uint16
Uint16
Int8
Int8
Uint16
-
Uint8
Uint16
-
Uint8
Uint8
Uint16
Uint16
Uint16
Uint8
Uint32
-
Uint8
Uint16
Uint16
-
Uint8
Uint8
-
Uint8
Uint16
103

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents