Download Print this page

Adjust Temperature Set Point/Adjust Differential; Manual Defrost/Factory Reset/Unlock Keypad; Typical Wiring Configurations; Technical Specifications - Danfoss ERC 213 Quick Start Manual

Refrigeration controller
Hide thumbs Also See for ERC 213:

Advertisement

Quick Start Guide, ERC 213
Common Functions

Technical Specifications

4 | 520H12295 | DKRCE.PD.RL0.A1.02
Adjust Temperature Set Point
From main screen, quickly press "set" (one
second). The current temperature setting will
appear on screen.
Cycle to intended temperature by pressing "^" or
"^" and press "set" to save. The display will return
to the main screen.
Adjust Differential
From main screen, press "set" for more than three
seconds.
Cycle to "r--" submenu by pressing " " or " " and
press "set. " Cycle to "r01" and press "set. " Cycle to
preferred differential setting, and press "set" to
save. "r01" will appear on screen. Press "<" twice
to return to main screen.
Manual Defrost
From main screen, press defrost for more than
three seconds to initiate defrost.
The DEFROST icon is shown during defrost.
Press defrost key for at least three seconds to
stop manual defrost.

Typical Wiring Configurations

ERC 213 - APP 1
Sair
(Control Sensor)
DI1 DI2
115 V AC
230 V AC
DO1
DO2
DO3
080G3268 115V AC 50/60 HZ;
Power Supply
080G3269 230V AC 50/60 Hz
Inputs
4 total; 2 analog, 1 analog / digital, 1 digital
Sensor Included in Kit
NTC 10000
D01 Compressor Relay
115 V (080G3268): 16 FLA / 72 LRA
230 V (080G3269): 10 FLA / 60 LRA
Output
D02 Defrost Relay and / D03 Fan Relay
8A, 2 FLA, 12 LRA
Operating Conditions
14 – 131 °F
Storage Conditions
-40 – 158 °F
UL Recognized / NSF
Factory Reset
Press and hold " " and " " simultaneously at
power up.
Unlock Keypad
After 5 minutes of no activity, the keypad will
lock if P76 = yes (by default it is set to no). When
the keypad is locked any key press shows "LoC"
in the display.
Press " " and " " simultaneously for three seconds
to unlock the keyboard. "unl" is displayed for
three seconds.
ERC 213 - APP 2-3
Sair
(Control Sensor)
DI1 DI2
115 V AC
230 V AC
DO1
DO2
DO3
ERC 213 - APP 4-5
Sair
(Control
S5
(Defrost)
Sensor)
DI1 DI2
115 V AC
230 V AC
DO1
DO2
DO3
© Danfoss | DCS (im) | 2017.08