Quick Set-Up; App Selection - Danfoss ERC 213 Quick Start Manual

Refrigeration controller
Hide thumbs Also See for ERC 213:

Advertisement

Quick Start Guide, ERC 213
Technical data

App Selection

Control
Application
Application
Code
AP0 (Default)
No preset application - full menu
AP1
Refrigeration
AP2
Refrigeration
AP3
Freezing
AP4
Refrigeration
AP5
Freezing
AP6
No preset application - simplified menu
*) Hot gas defrost is an option available in full menu (d01).
2 | 520H12295 | DKRCE.PD.RL0.A1.02

Quick Set-up

STEP
Action
STEP 1
Wire control, to include power and sensors
Power up control
STEP 2
Energize control
Enter Quick Configuration Menu and Select app
Press "<" for more than three seconds within one minute
of power up to enter Quick Configuration Menu.
STEP 3
Press "set" while o61 is on screen
Select appropriate app using App Selection section
below by pressing " " or " ", then press "set".
Select Sensor
Press "set" while o06 is on screen
If using included sensor, leave default value "n10". If using
STEP 4
another sensor, select using Sensor Resistance section
below or cycle through steps 2 – 4 changing the sensor
type until the temperature reading on the main screen
is accurate. As above, cycle between options by pressing
" " or " " and press "set" to save.
Set Temperature
From main screen, quickly press "set" (1 second).
STEP 5
Cycle to intended temperature by pressing " " or " " and
press "set" to save.
Select application based on application and
wiring configuration (i.e., refrigeration vs.
freezing, and number of temperature sensors).
The Typical Wiring Configurations diagram on
the reverse side of this document may be used
Defrost
Defrost
Sensors
Type*)
Termination
2
Natural
Time
1
Electric
Time
1
Electric
Time
1
Electric
Temp.
2
Electric
Temp.
2
2
to assist with selection. All parameters can be
modified using the full menu. Some parameters
have min and max set points which may need to
be changed for less common configurations.
Temp. Range
Default
Default
min. / max.
Temp. [°F]
Dif. [°F]
[°F]
[r00]
[r01]
[r02/r03]
36
-31 / 22
39
36 / 43
36
32 / 39
-11
-15 / -4
36
32 / 39
-11
-15 / -4
36
-31 – 122
Screen Display
Control turns on, goes through start up, then
shows the current temperature reading
o61 appears on screen
AP0 flashes on screen
o06 appears on screen
n10 flashes on screen
o06 appears on screen, then control resets
Current temp. setting appears on screen
Screen returns to main screen
Defrost
Max.
Interval
Defrost
[hrs]
Time [mins]
[d03]
[d04]
4
6
30
4
4
30
4
6
15
4
6
15
4
6
30
4
6
30
4
6
30
© Danfoss | DCS (im) | 2017.08
Defrost
Termination
Temp. [°F]
[d02]
43
43
43
43