Commissioning
Parameter
Pulse value
Switch output simulation
Switch status
Simulation device alarm
Simulation diagnostic event
Diagnostic event category
Simulation diagnostic event
80
Prerequsite
The Down-count. val. option
is selected in the Simulation
pulse output parameter.
The On option is selected in
the Switch output simulation
parameter.
10.8
Protecting settings from unauthorized access
The following options exist for protecting the configuration of the measuring device from
unintentional modification after commissioning:
• Write protection via access code (→  80)
• Write protection via write protection switch (→  81)
• Write protection via keypad lock (→  44)
• Write protection via block operation (→  82)
10.8.1

Write protection via access code

With the customer-specific access code, the parameters for the measuring device
configuration are write-protected and their values can no longer be changed via local
operation.
Navigation
"Setup" menu → Advanced setup → Administration → Define access code
Structure of the submenu
Define access code
Proline Promass E 200 FOUNDATION Fieldbus
Description
Enter the number of pulses for
simulation.
Switch simulation of switch
output on and off.
Select the status of the status
output for the simulation.
Switch the device alarm on and
off.
Switch simulation of the
diagnostic event on and off.
For the simulation, you can
choose from the diagnostic
events of the category selected
in the Diagnostic event
category parameter.
Select the category of the
diagnostic event.
Switch simulation of the
diagnostic event on and off.
For the simulation, you can
choose from the diagnostic
events of the category selected
in the Diagnostic event
category parameter.
Define access code
Confirm access code
Selection / User
Factory setting
entry
0 to 65 535
0
• Off
Off
• On
• Open
Open
• Closed
• Off
Off
• On
• Off
Off
• Picklist
Diagnostic events
(depends on the
selected category)
• Sensor
Process
• Electronics
• Configuration
• Process
• Off
Off
• Picklist
Diagnostic events
(depends on the
selected category)
Endress+Hauser