Appendix
Relative
Index
46
TRDASUP_PFS_StateSwitchOnDelay_1
47
TRDASUP_PFS_StateSwitchOffDelay_1
48
TRDASUP_PFS_StateFailsafeMode_1
49
TRDASUP_PFS_StateOutValue_1
50
TRDASUP_PFS_OutSignalInvert_1
51
TRDASUP_STD_SWOptionActiveOverview_1
52
TRDASUP_SU_MassFlow_1
53
TRDASUP_SU_Mass_1
54
TRDASUP_SU_VolumeFlow_1
55
TRDASUP_SU_Volume_1
56
TRDASUP_SU_CorrVolume_1
57
TRDASUP_SU_CorrVolumeFlow_1
58
TRDASUP_SU_Density_1
59
TRDASUP_SU_RefDensity_1
60
TRDASUP_SU_Temperature_1
61
TRDASUP_TIC_Channel_1
62
TRDASUP_TIC_TotUnit_1
63
TRDASUP_TIC_Channel_2
64
TRDASUP_TIC_TotUnit_2
65
TRDASUP_TIC_Channel_3
66
TRDASUP_TIC_TotUnit_3
67
TRDASUP_SU_Pressure_1
68
TRDASUP_CFM_MeasCarrTubeTemp_1
69
TRDASUP_SU_Length_1
TRDASUP_View1
TRDASUP_StRev
TRDASUP_BlockErr
TRDASUP_TransducerType
TRDASUP_XdError
TRDASUP_BlockErrDesc_1
STD_LockingState
PFS_PulseOutValue
PFS_FrequencyOutValue
TRDASUP_View2
TRDASUP_StRev
TRDASUP_TransducerType
144
Name
Switch-on delay
Switch-off delay
Invert output signal
Software option
Mass flow unit
Volume flow unit
Corrected volume
Corrected volume
Reference density
Temperature unit
Assign process
Assign process
Assign process
Measure supported
Static Revision
Transducer Type
Transducer Error
Locking status
Output frequency
Static Revision
Transducer Type
Proline Promass E 200 FOUNDATION Fieldbus
Label
Data type
FLOAT
FLOAT
Failure mode
ENUM16
Switch status
ENUM16
ENUM16
BIT_ENUM32
overview
ENUM16
Mass unit
ENUM16
ENUM16
Volume unit
ENUM16
ENUM16
unit
ENUM16
flow unit
Density unit
ENUM16
ENUM16
unit
ENUM16
ENUM16
variable
Unit totalizer
ENUM16
ENUM16
variable
Unit totalizer
ENUM16
ENUM16
variable
Unit totalizer
ENUM16
Pressure unit
ENUM16
Carrier
ENUM16
Temperature
Length unit
ENUM16
View -1-
VIEW1
UINT16
Block Error
BIT_ENUM16
ENUM16
ENUM8
Block error
BIT_ENUM32
description
BIT_ENUM16
Pulse output
FLOAT
FLOAT
View -2-
VIEW2
UINT16
ENUM16
Storage
Size
MODE_BLK Writability
Class
(Bytes)
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Dynamic
2
Static
2
AUTO
Static
4
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Dynamic
25
Static
2
Dynamic
2
Static
2
Dynamic
1
Dynamic
4
Dynamic
2
Dynamic
4
Dynamic
4
Static
26
Static
2
Static
2
Endress+Hauser
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Hide quick links: