Transducer Block Expert Info - Endress+Hauser Proline Promass E 200 Operating Instructions Manual

Coriolis flowmeter
Hide thumbs Also See for Proline Promass E 200:
Table of Contents

Advertisement

Appendix
Relative
Index
TRDEXP_StRev
TRDEXP_Strategy
TRDEXP_AlertKey
TRDEXP_TransducerType
FLOW_FlowDampingTime
FLOW_DensityDampingTime
FLOW_PositivZeroReturn
FLOW_TemperatureDampingTime
FLOW_DensityMonitoringSelector
FLOW_MassFlowOffset
FLOW_MassFlowScale
FLOW_VolumeFlowOffset
FLOW_VolumeFlowScale
FLOW_CorrVolumeFlowOffset
FLOW_CorrVolumeFlowScale
FLOW_DensityOffset
FLOW_DensityScale
FLOW_RefDensityOffset
FLOW_RefDensityScale
FLOW_TemperatureOffset
FLOW_TemperatureScale
Relative
Index
11
TRDEXPIN_TransducerTypeVer
12
TRDEXPIN_XdError
13
TRDEXPIN_CollectionDirectory
14
TRDEXPIN_BlockErrDesc_1
15
TRDEXPIN_STD_UserLevel_1
16
TRDEXPIN_STD_LockingState_1
17
TRDEXPIN_STD_LicenseCode_1
18
TRDEXPIN_STD_SWOptionActiveOverview_1
162
Name
17.1.6

Transducer Block Expert Info

Name
Transducer Error
Access status
Locking status
Activate SW option
Software option
Proline Promass E 200 FOUNDATION Fieldbus
Label
Data type
Static Revision
UINT16
Strategy
UINT16
Alert Key
UINT8
Transducer Type
ENUM16
Flow damping
FLOAT
Density damping
FLOAT
Flow override
ENUM16
Temperature
FLOAT
damping
Assign process
ENUM16
variable
Mass flow offset
FLOAT
Mass flow factor
FLOAT
Volume flow
FLOAT
offset
Volume flow
FLOAT
factor
Corrected volume
FLOAT
flow offset
Corrected volume
FLOAT
flow factor
Density offset
FLOAT
Density factor
FLOAT
Reference density
FLOAT
offset
Reference density
FLOAT
factor
Temperature
FLOAT
offset
Temperature
FLOAT
factor
Label
Data type
UINT16
ENUM8
Collection
UINT32
Directory
Block error
BIT_ENUM32
description
ENUM16
tooling
BIT_ENUM16
UINT32
BIT_ENUM32
overview
Storage
Size
MODE_BLK Writability
Class
(Bytes)
Static
2
Static
2
AUTO
Static
1
AUTO
Static
2
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Storage
Size
MODE_BLK Writability
Class
(Bytes)
Static
2
Dynamic
1
Static
4
Dynamic
4
Static
2
Dynamic
2
Static
4
AUTO
Static
4
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Endress+Hauser

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline Promass E 200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents