Panic Alarm Pgm Option (Esprit Mode Only) - Paradox MG-RCV3 Reference And Installation Manual

Wireless expansion module v1.0
Hide thumbs Also See for MG-RCV3:
Table of Contents

Advertisement

How to set the panic lockout timer.
In step 4 in section 3.2 on page 10:
1. Enter section [26].
2. Enable only one option from [0] to [4] (refer to Table 6.2 on page 19).
3. Press [
ENTER

6.3 Panic Alarm PGM Option (Esprit mode only)

[35]:
SECTION
When a remote control activates a panic alarm, the MG-RCV3 can either
toggle only the remote control's enabled PGM output (refer to section 6.1 on
page 18) or toggle the remote control's enabled PGM output and send a panic
alarm code to the Esprit control panel.
How to set the panic alarm PGM option.
In step 4 in section 3.2 on page 10:
1. Enter section [35].
2. Enable or disable option [2].
3. Press [
ENTER
Magellan Wireless Expansion Module
].
Table 6.2: Panic Lockout Timer
Key [0] ON = No RF signal lockout on panic alarm (default)
Key [1] ON = 30-second RF signal lockout on panic alarm
Key [2] ON = 60-second RF signal lockout on panic alarm
Key [3] ON = 90-second RF signal lockout on panic alarm
Key [4] ON = 120-second RF signal lockout on panic alarm
[2]
OPTION
Option [2] OFF = Toggle the enabled PGM output only.
Option [2] ON = Toggle the enabled PGM output and send a
].
panic alarm code.
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents