Panic Alarm Programming; Panic Output Programming (Esprit Mode Only); Panic Lockout Timer (Esprit Mode Only); Panic Outputs - Paradox MG-RCV3 Reference And Installation Manual

Wireless expansion module v1.0
Hide thumbs Also See for MG-RCV3:
Table of Contents

Advertisement

6.0 Panic Alarm Programming

If the panic alarm feature is enabled for the remote control (refer to section 4.3.3 on
page 13), pressing buttons
will generate a panic alarm.

6.1 Panic Output Programming (Esprit mode only)

[25]:
SECTION
When a remote control activates a panic alarm, the MG-RCV3 can be
programmed to activate one of the four on-board PGM outputs. Enable one of
the options from [0] to [4] (refer to Table 6.1 on page 18) by pressing the
corresponding keypad key.
How to program the panic outputs.
In step 4 in section 3.2 on page 10:
1. Enter section [25].
2. Enable only one option from [0] to [4] (refer to Table 6.1 on page 18).
3. Press [
ENTER

6.2 Panic Lockout Timer (Esprit mode only)

[26]:
SECTION
When a remote control activates a panic alarm, the MG-RCV3 can be
programmed to ignore any incoming remote control (RF) signals for a specified
time period. Enable one option from [0] to [4] (refer to Table 6.2 on page 19) by
pressing the corresponding keypad key.
18
(refer to Figure 4.2 on page 13) simultaneously
+
[0]
[4]
OPTIONS
TO
].
Table 6.1: Panic Outputs
Key [0] ON = No PGM output on panic alarm
Key [1] ON = Toggle PGM 1 on panic alarm
Key [2] ON = Toggle PGM 2 on panic alarm
Key [3] ON = Toggle PGM 3 on panic alarm (default)
Key [4] ON = Toggle PGM 4 on panic alarm
[0]
[4]
OPTIONS
TO
Reference & Installation Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents