Component
1
UV low pressure lamps, facial tanner
2
UV low pressure lamps, base
4
UV low pressure lamps, canopy
1
UV low pressure lamps, facial tanner
1
Starter UV low pressure lamps,
facial tanner
3
Acrylic glass panel
1
Facial tanner filter panels
7
Starter
5, 6
Starter
*
07/2015
1016259-00A
Interval
X
X
X
X
* Contact the customer service if the accent lighting in the canopy fails.
4.7
Cleaning and
maintenance work preparation
4.7.1
Lift up the acrylic glass panel
–
Lift up the acrylic glass panel.
–
Lift up the supports and prop the acrylic glass panel on them.
WARNING!
Risk of scratching!
Use the recesses provided on the acrylic glass panel.
–
Remove the lamp covers at the head and foot ends.
Cleaning and maintenance
Activity
Replace
Replace
Replace
Replace
X
Replace
X
Replace
X
Visual control
X
Replace
X
Replace
Operating instructions – 37/58
See page
45
44
45
45
45
36
45
42
–