16. Performing Non-Image Area Erase
Check
Note:
Perform the below at the site where customer
uses the machine.
(1) Select the Non-Image Area Erase Check func-
tion as follows:
Machine → Non-Image Area Erase Check.
(2) Open fully the reverse automatic document
feeder or the original cover if loaded.
Note:
• Do NOT place a document on the document
glass.
• Clean the document glass if dirty.
(3) Press the Start key.
(4) Make sure that "Result" is "OK."
Note:
If "Result" is "NG1" or "NG2", review the place and
direction of installation, or take measures to block
the light source (by covering it, etc.), then perform
installation checking again.
(If a fluorescent light or other bright light sources
exist right above the machine, the light source can
hinder installation checking and cause operation
errors in the Non-Image Area Erase Check. For
detailed information, see the service manual.)
(5) Touch "OK."

17. Configuring other options

(1) If any of the following options are installed, refer
to the installation manual for each option and
configure the option(s).
• Reverse Automatic Document Feeder DF-628
• Stamp Unit SP-501
• Fax Kit FK-513
• Punch Kit PK-520/PK-519
• Upgrade Kit UK-212/UK-211
• Paper Feed Cabinet PC-413
• Hard Disk HD-522
(Do not perform this procedure for options
already installed as standard equipment.)
• Authentication Unit AU-201S/AU-102
• Network Fax
Note:
The installation manual for each option contains
the following caution for completion of settings:
"When displayed the Service Mode screen, be
sure to turn off the power after exiting the Service
Mode screen and wait for 10 seconds or more
before turning on." However, since all settings are
made at the same time in accordance with "20.
Restarting the machine" in this installation manual,
you do not need to turn the power off and on again
after configuring each individual option.
(2) Exit from the Service Mode and return to the ini-
tial screen.

18. Connecting the network cable

(1) Connect the main body and networking equip-
ment (HUB) using the network cable.
Note:
The following shows the recommended network
cables that correspond to each communication
speed.
• 10BaseT/100BaseTX: Category 5
• 1000BaseT: Category 5E, Category 6
(2) Check LEDs for lighting conditions.
LED1:
Should light up steadily if the link network con-
nection has been made.
LED2:
Should blink according to the communications
status of the ACT network.
E-8
LED2
LED1
Networkport