Rate - TESTO 454 Instruction Manual

Hide thumbs Also See for 454:
Table of Contents

Advertisement

testo
Program

Rate

˛
1
s
Ein
Enter /
On
0
20
8
8.3.3.2 Rate
Specify the rate at which the measuring instrument
should save the probe data during this measurement.
Entries from 0.1 seconds to 24 hours are possible.
Seconds can be given in fractions. Minutes and hour-
ly rates are usually whole numbers. All values are
saved according to the probes connected.
Please note that some measuring time must be
allowed for each connected probe since the sockets
must be serially checked.
The probe with the longest measuring time
defines the minimum measuring rate.
The following is the time required for each probe:
Hum. probe °C/%RH w. dew-point .0.3 seconds
Vanes . . . . . . . . . . . . . . . . . . . . . . . .0.7 seconds
Shell anemometer . . . . . . . . . . . . . .2.2 seconds
Frequency sources . . . . . . . . . . . . .0.7 seconds
Pt100 probes
. . . . . . . . . . . . . . . . .0.1 seconds
Other . . . . . . . . . . . . . . . . . . . . . . . .0.2 seconds
In the menu M
(See Chap. 8.3.4) the short-
.
IN
RATE
est measuring rate depending on the probes con-
nected can be checked.