1 Contents

1 Contents .............................................................................................. 1
2 System ................................................................................................ 3
2.1 System overview .................................................................................... 3
3 First steps ............................................................................................ 4
4 Offline Konfiguration ............................................................................ 5
5 Licences .............................................................................................. 6
1.1 testo Saveris 2 App ................................................................................ 6
6 WiFi data logger ................................................................................... 8
6.1 Technical data ........................................................................................ 8
6.1.1
Measurement-specific data ..................................................... 8
6.1.2
General data ............................................................................ 9
6.1.3
WiFi-specific data .................................................................. 12
6.1.4
Technical data for a secure wireless LAN.............................. 12
6.1.5
Authorizations ........................................................................ 14
6.1.5.1
6.1.5.2
6.1.5.3
6.1.5.4
6.1.5.5
6.1.5.6
6.1.5.7
6.1.5.8
6.1.5.9
6.1.5.10
6.1.5.11
6.1.6
Authorizations (2016) ............................................................. 21
6.2 Safety and the environment ................................................................. 24
1.1.1
General safety instructions .................................................... 24
1.1.2
implanted cardiac pacemaker ............................................... 25
1.1.3
Batteries ................................................................................ 25
1.1.4
Protecting the environment ................................................... 25
6.3 Wall bracket ......................................................................................... 26
European Union, EFTA countries .......................... 14
USA/Canada ......................................................... 19
Japan .................................................................... 20
Australia ................................................................ 20
China .................................................................... 20
Korea .................................................................... 20
Russia ................................................................... 21
Chile ...................................................................... 21
Singapore ............................................................. 21
Ukraine ................................................................. 21
United Arab Emirates ............................................ 21

Advertisement

Table of Contents
loading

Summary of Contents for TESTO Saveris 2

  • Page 1: Table Of Contents

    2.1 System overview ..................3 3 First steps .................... 4 4 Offline Konfiguration ................5 5 Licences ....................6 1.1 testo Saveris 2 App ................6 6 WiFi data logger ................... 8 6.1 Technical data ..................8 6.1.1 Measurement-specific data ............. 8 6.1.2...
  • Page 2 6.4 Display and control elements .............. 28 6.4.1 Overview ................28 6.4.2 Display icons ................. 28 6.4.3 LED display – configuration ..........29 6.4.4 LED display – operation ............30 7 User interface ..................31 8 Dashboard ..................32 8.1 Measuring points ................. 32 8.2 Active alarms ..................
  • Page 3: System

    2 System 2.1 System overview The testo Saveris 2 WiFi data logger system is the modern solution for monitoring temperature and humidity values in storerooms and work rooms. The system consists of WiFi data loggers and a Cloud data storage system.
  • Page 4: First Steps

    Tighten the screws on the back of the housing back up. The Quick Start Guide is provided to assist you when you take your first steps with commissioning the testo Saveris 2. It can help you with logging in WiFi data loggers.
  • Page 5: Offline Konfiguration

    Open the file WifiConf.pdf on the external drive SAVERIS 2. Copy your Account ID and paste it into the relevant field on the PDF form. You will find the Account ID in the testo Saveris 2 software under Configuration -> Account ID.
  • Page 6: Licences

    Click on the checkbox in front of the recipient to send push messages. Please note that the free testo Saveris 2 App must be installed on your Android or iOS device to receive push messages.
  • Page 7 Android devices Alarms With the testo App, you can receive all Saveris 2 push alerts and see an overview. In order to be able to establish a connection, you need a tablet or smartphone with the testo App already installed on it.
  • Page 8: Wifi Data Logger

    Not for condensing atmosphere. For continuous application in high humidity (> 80% RH at ≤ 30 °C for > 12 h, > 60% RH at > 30 °C for > 12 h), please contact us (www.testo-international.com).
  • Page 9: General Data

    0.1 °C Probe-specific 0.1% RH Saveris 2 WiFi data loggers are supplied with a factory calibration certificate as standard. In many applications, it is recommended that you recalibrate the loggers every 12 months. This can be carried out by Testo Industrial Services (TIS) or other certified service providers with the aid of easy-to-use service software.
  • Page 10 WiFi data logger Order number 0572 2001 0572 2002 0572 2003 0572 2004 0572 2005 Memory 10,000 readings/channel Battery life 12 months at +25 °C, 15 min measuring cycle, 30 min day communication cycle (8 h/day) and 120 min night communication cycle (16 h/day) at -30 °C and 15 min measuring cycle, 30 min day communication cycle (8 h/day)
  • Page 11 WiFi data logger Order number 0572 2031 0572 2032 0572 2033 0572 2034 0572 2035 Communication 1 min to 24 h (15 minutes default) cycle Memory 10,000 readings/channel Battery life 12 months at +25 °C, 15 min measuring cycle, 30 min day communication cycle (8 h/day) and 120 min night communication cycle (16 h/day) at -30 °C and 15 min measuring cycle, 30 min day communication cycle...
  • Page 12: Wifi-Specific Data

    EAP-PEAP0-TLS, EAP-PAP0-MSCHAPv2, EAP-PEAP0-PSK, EAP-PEAP1-TLS, EAP-PEAP1-MSCHAPv2, EAP-PEAP1-PSK 6.1.4 Technical data for a secure wireless LAN Ports The testo Saveris 2 WiFi data loggers use the MQTT protocol, which communicates via port TCP 1883 or 8883 These UDP port approvals are also required: •...
  • Page 13 DHCP or Static IP is used (select expert mode for the corresponding information) testo Saveris 2 application The testo Saveris 2 application is accessible via a normal, up-to-date browser (www). The standard TCP ports http (80) and https (443) are used.
  • Page 14: Authorizations

    6.1.5 Authorizations 6.1.5.1 European Union, EFTA countries T1 (0572 2001):...
  • Page 15 T2 (0572 2002):...
  • Page 16 T3 (0572 2003):...
  • Page 17 H1 (0572 2004):...
  • Page 18 H2 (0572 2005):...
  • Page 19: Usa/Canada

    6.1.5.2 USA/Canada This instrument complies with Part 15C of the FCC Rules and Industry Canada RSS-210 (revision 8). Commissioning is subject to the following two conditions: (1) This instrument must not cause any harmful interference and (2) this instrument must be able to accept interference, even if this could have undesired effects on operation.
  • Page 20: Japan

    Saveris 2 Saveris 2 Saveris 2 Saveris 2 H1 Saveris 2 H2 model Identification MSIP-CRM- MSIP-CRM- MSIP-CRM- MSIP-CRM-Toi- MSIP-CRM-Toi- number Toi- Toi- Toi- Saveris2H1 Saveris2H2 Saveris2T1 Saveris2T2 Saveris2T3 Applicant Testo Instruments (Shenzen) Co., Ltd. Manufacturer Testo Instruments (Shenzen) Co., Ltd.
  • Page 21: Russia

    Authorized. 6.1.5.10 Ukraine Authorized. 6.1.5.11 United Arab Emirates Authorized. 6.1.6 Authorizations (2016) Approval and Certification Saveris 2 T1 (2016) Saveris 2 T2 (2016) Product Saveris 2 T3 (2016) Saveris 2 H1 (2016) Saveris 2 H2 (2016) 0572 2031 0572 2032 Mat.-No.
  • Page 22 IC: 6127B-0572203X IC: 6127B-05722034 IC Warnings Europa + EFTA The EU Declaration of Conformity can be found on the testo homepage www.testo.com under the product specific downloads. EU countries: Belgium (BE), Bulgaria (BG), Denmark (DK), Germany (DE), Estonia (EE), Finland (FI), France (FR), Greece (GR), Ireland...
  • Page 23 Contains FCC ID: N8NLSD4WF0459 T1, T2, T3, H2: FCC ID: WAF-0572203X FCC ID: WAF-05722034 FCC Warnings Wi-Fi-Module Feature Values WLAN Range 100 m WLAN type LSD4WF0459-01D0 WLAN radio class Accord with the standard of IEEE 802.11b/g/n Company Lierda Technology Group co., LTD RF Band 2412-2472MHz Transmitter Power...
  • Page 24: Safety And The Environment

    Do not commission the instrument if there are signs of damage on the housing. • Only use accessories and probes configured for Saveris 2. • Dangers may also arise from the systems being measured or the measuring environment: always comply with the locally valid safety regulations when carrying out measurements.
  • Page 25: Safety Instructions For Patients With A Cardiac Pacemaker Or Implanted Cardiac Pacemaker

    Dispose of spent batteries in accordance with the relevant legal specifications. • At the end of its useful life, deliver the product to the separate collection point for electric and electronic devices (observe local regulations) or return the product to Testo for disposal.
  • Page 26: Wall Bracket

    6.3 Wall bracket Note The data loggers must only be mounted vertically. Here, the connections must point downwards. In the case of data loggers with a display, you need to pay attention to the reading direction. Otherwise, the measuring accuracy might be diminished. The wall bracket ensures that the WiFi data logger is kept securely in place.
  • Page 27 (Suitable for: 0572 2034) Wall bracket Data logger Unlocking tool Magnetic plate (optionally available, order number: 0554 2001) • Insert the unlocking tool into the unlocking opening. • Pull the data logger up and out of the wall bracket.
  • Page 28: Display And Control Elements

    6.4.1 Overview Display Alarm LED, flashes red in the event of an alarm QR code, for direct access to the instrument data in the Testo Cloud Control key, to manually start data transfer Battery compartment (on rear) USB and probe sockets (on the bottom, instrument-specific) 6.4.2 Display icons...
  • Page 29: Led Display - Configuration

    Icon Description WLAN signal strength 75% WLAN signal strength 50% WLAN signal strength 25% Data connection to the Testo Cloud exists, icon flashes: Data connection to the Testo Cloud being established Alarm message Measurement channel 1 Measurement channel 2 Alarm status: upper limit value exceeded Alarm status: lower limit value undershot 6.4.3 LED display –...
  • Page 30: Led Display - Operation

    6.4.4 LED display – operation LED display Description Online data logger which is already Online data logger is not connected to the configured gives 2 short red flashes. access point, measurement data cannot be transmitted to the Cloud. Online data logger gives 1 long The online data logger has carried out a green flash.
  • Page 31: User Interface

    7 User interface System and status information (see page 43) Command bar (see page 43) User management (see page 42) Menu bar with the main menus: • Dashboard (see page 32) • Analysis & reports (see page 32) • Alarms (see page 34) •...
  • Page 32: Dashboard

    8 Dashboard The dashboard is the home page. It provides an overview of the key system data: Measuring points and Active alarms. 8.1 Measuring points A summary of all measuring points is displayed. Click on the icon to display more information. 8.2 Active alarms A summary of all active alarms and system warnings is displayed.
  • Page 33 • Also send report via e-mail: as well as saving reports under Generated reports, these can also be sent as e-mails. Click on the checkbox to open the input screen for e-mail addresses. Click on the Create an automatic report button. The first report will be created on the following day.
  • Page 34: Alarms

    10 Alarms 10.1 Alarm list Display of alarms A summary of all triggered alarms and system warnings is displayed. Unread alarms and system warnings are shown in bold. The display can be filtered according to the following characteristics: • By measuring point group/measuring point: click on the checkbox in front of the measuring point group/measuring point.
  • Page 35: System Warnings

    The time intervals between measurements (measurement rate should be smaller than the alarm delay (e.g. measurement rate = 5 minutes, alarm delay = 15 minutes). • Timed control: Define individual alarm periods for which the alarm limit values 1 and 2, or no alarm at all, apply. To define the alarm value 1 and 2, double-click on a time point in the table or pull open the desired time period with the mouse.
  • Page 36 • WiFi data logger is not responding: monitor the WiFi data logger for data transmission failure. Click on the Activate button and configure the monitoring cycle using the slide control. Note The set time should be greater than the WiFi data logger's communication cycle.
  • Page 37: Configuration

    Account Owner (name can be changed), with Administrator user role (role cannot be changed). • Testo Support (name can be changed), with Testo User Support user role (role cannot be changed). Creating and editing new users Other users with different User roles (see page 38) can be created and edited.
  • Page 38: User Roles

    = available, - = not available 11.3 Account ID The Account ID is the unique address of your user account in the Testo Cloud. This is needed to configure the WiFi data loggers in order to ensure that they...
  • Page 39: Measuring Point Groups

    11.4 Measuring point groups Measuring points can be organized into measuring point groups. Assigning measuring points to a measuring point group (e.g. Room 1, Room 2, etc.) makes the administration of multiple measuring points easier. See also Areas, page 40. Creating and editing a measuring point group •...
  • Page 40: Areas

    11.5 Areas Measuring point groups can be organized into areas. See also Measuring point groups, page 39. Creating and editing an area • Click on the New area button to create a new area. Areas already created are displayed in a list. •...
  • Page 41: Firmware Updates

    • Day communication cycle and Night communication cycle: interval at which readings are transmitted to the Testo Cloud. Select the start time for the day communication cycle and the night communication cycle. Set the communication cycle using the slide control.
  • Page 42: User Management

    • Save: click on the button to save the settings. 12.2 Account information Information about your Saveris 2 account is displayed. 12.3 Change password The user password can be changed. New password and New password (repeat): enter new password in both text fields.
  • Page 43: Command Bar

    13 Command bar 13.1 Open Quick Start Guide The Quick Start Guide can help you with logging in WiFi data loggers. • Click on the icon to open the Quick Start Guide. 13.2 Open Online Help The Online Help (this document) provides support for issues related to the product components.
  • Page 44: Frequently Asked Questions

    Longer USB cables are suitable for the power supply only. Can the WiFi data logger also be used in networks with WPA2 Enterprise encryption? Second-generation Saveris 2 loggers* can be used in networks with the following WPA2 Enterprise encryption methods. EAP-TLS, EAP-TTLS-TLS, EAP-TTLS-MSCHAPv2, EAP-TTLS-PSK, EAP-PEAP0-TLS, EAP-PAP0-...
  • Page 45 The WiFi data logger is displaying the error code E03, E04, E05 or E09, what can I do? An error has occurred in the WiFi data logger. The error will automatically be corrected by the firmware of the WiFi data logger. After a few seconds the error code should no longer be displayed, you do not need to do anything.
  • Page 46 A WPA2 Enterprise EAP-TLS connection needs to be configured, but no private key could be found. Save the private key in PEM format under the name “private.key” together with the XML file or upload it in the web config. The WiFi data logger is displaying error code E25, what can I do? Incorrect format of the private.key certificate.
  • Page 47 The servers will be monitored and should be accessible again within a few hours. If the WiFi data logger has not yet been connected to the Testo Cloud: The TCP ports (1883 or 8883) of the access point (WLAN router) are not open.
  • Page 48 I do? The WiFi data logger cannot be logged on because the number of WiFi data loggers permitted to log on has been exceeded or your testo Saveris 2 licence has expired. Log off another WiFi data logger, extend or renew your testo Saveris 2 licence.
  • Page 49: Change History

    16 Change history Information about changes to the testo Saveris 2 Cloud: Revision Release date Improvements 10351 2015-03-26 • Automatic reports can now be created • Vertical help lines in the PDF report were optimized • SMS alarms can now be sent in Russian, Japanese, Chinese and Turkish.
  • Page 50 Revision Release date Improvements Internet Explorer 8 • The switchover of a T2 channel from temperature to door contact has been improved • The texts for e-mail and SMS alarms have been revised • The stability of communication between the probes and the Cloud has been improved •...
  • Page 51 Revision Release date Improvements sometimes still had alarm settings stored after a hardware reset, has been rectified • The error that the set user language was not taken into account in the setting of the communication rate, has been rectified •...
  • Page 52 • Suspended alarms are now identified as such • Alarm limit values outside the physical limits of the testo Saveris 2 probes can no longer be entered (e.g. 105 %RH) 10955 2015-04-07 • The quick start guide is adapted to the new licence model •...