Sensor temperature calibration example:
If sensor reading value = 77
Display temperature = sensor reading value + offset value
If using decimal input: Parameter no. = 10; Parameter value = -2
If using hexadecimal input: Parameter no. = 0x0A; Parameter value = FE (Size >= 1 byte)
Reset ZTS-500 to Factory Default Settings
Warning:
Please use this procedure only when the network primary
controller is missing or otherwise inoperable.
Step
Procedure / Description
Press and keep holding > or < for 3 seconds to
navigate to the System Main (SYS) screen.
1
Press > to navigate to the Reset (RST) screen.
Press + or – to entry the setting.
Press + or - to select Yes.
Press and keep holding > for 2 seconds to
2
confirm your selection.
Press < to cancel and back to the previous
screen.
Note:
If the user performs a Reset to Factory Default Settings, all settings, Z-Wave configuration
parameter values and association groups information will reset to default. The ZTS-500 will retain
the last selected HVAC system type.
o
F, offset value = -2
o
o
= 77-2
F = 75
F
9 (0x09) = 4.5 hrs
10 (0x0A) = 5.0 hrs
11 (0x0B) = 5.5 hrs
12 (0x0C) = 6.0 hrs
13 (0x0D) = 6.5 hrs
14 (0x0E) = 7.0 hrs
15 (0x0F) = 7.5 hrs
16 (0x10) = 8.0 hrs
O
F