01.01.2016
HEATIT Z-WAVE

Installation guide

SW 1.7
·
STANDARD COLOR
White RAL 9003 – Black RAL 9011
·
APPROVALS
CE – Z-Wave Plus
IMPORTANT!
PLEASE READ THIS BEFORE INSTALLATION.
This thermostat is tested and certifi ed by Pepper One Gmbh
according to the requirements put forward by the Z-Wave
Alliance. This is a Z-Wave Plus product with the 500 series chip.
If the product does not work with your gateway, then the
gateway manufacturer has not made an integration or
implemented such a thermostat with their gateway. We do not
give any guarantee towards integration.
PRINCIPLES FOR REGULATION
The Heatit Z-Wave is designed for controlling electrical heating
cables and electrical radiators/convectors. The thermostat
has 2 internal temperature sensors and has 3 algorithms for
temperature compensation.
After you have set the temperature, the thermostat will use
a hysteresis to regulate the temperature. The hysteresis is
adjustable.
TEMPERATURE SHOWN IN DISPLAY
The temperature shown in the display is the actual temperature
for fl oor sensor and the external room sensor. You are able to
calibrate the sensor values.
When using the internal room sensor, the temperature shown is
the set point. Due to the internal heat buildup in the thermostat,
we do not recommend to use this function. This makes the
thermostat sensitive towards draft in the connection box.
If the thermostat is to be used with waterbased heating systems,
you have to use an external sensor.
Z-WAVE THERMOSTAT – SETUP
This manual describes the most essential functions and
technical specifi cations of the thermostat.
These instructions help the user to control the thermostat, and
the electrician to install and setup the thermostat.
INSTALLATION
Installation must be done by a qualifi ed Electrical Installer in
accordance with the National Building codes. Before installation,
disconnect any power to the thermostat's mains. During
installation of the thermostat, power to the thermostat must be
disconnected AT ALL TIMES!
Use e.g. a small slotted screwdriver. The front cover and the
frame can now be removed.
Now connect the wires to the thermostat's terminals:
HEATING (N)
N
L
HEATING (L)
PILOT
FLOOR SENSOR
EXTERNAL SENSOR
Next, position the thermostat and fasten it onto the wall's
mounting box using 2-4 screws. Position the frame, then
position and carefully press the front cover until it snaps in
place. Check that the front cover has snapped in place properly
on both left and right side. The front cover should now be fi rmly
fi xed on all sides.
·
DISPLAY
STARTUP
AFTER CONNECTING THE POWER TO THE THERMOSTAT FOR THE
FIRST TIME, ALL PARAMETERS WILL DEFAULT SETTINGS.
2 yr
TF 021
Made in EU
Mål på Z-wave-logo: 10mm x 8mm
Heating cable connection (Neutral)
Power connection (Neutral) 230V
Power connection (Live) 230V
Heating cable connection (Live)
230V pilot signal
NTC type (10, 12, 15, 33 or 47kΩ). Default 10kΩ.
NTC type (10, 12, 15, 33 or 47kΩ). Default 10kΩ.
LED-display 3x 7-Seg 13.2mm CA white

Advertisement

loading

Summary of Contents for Z-Wave 5430499

  • Page 1: Installation Guide

    Z-Wave Alliance. This is a Z-Wave Plus product with the 500 series chip. Now connect the wires to the thermostat’s terminals: If the product does not work with your gateway, then the...
  • Page 2 NTC-sensors · Power regulator · Lock mode/child lock INCLUSION/EXCLUSION To include the thermostat to your home automation gateway, · Z-Wave Plus chip, 500 series · Backlight press Center (confirm) for 10 seconds. · Weekly program · Calibration The display will show OFF. Press Right (down) 4 times till you see ·...
  • Page 3 0.2°C up to max 3.0°C. Confirm with Center (confirm) button. Default setting is 0.5°C. When using a waterbased ASSOCIATIONS system the hysteresis should be min 1.0°C. Association enables the thermostat to control a device e.g a relay or a wallplug, that is included in your z-wave network.
  • Page 4 18°C (5°C 40°C) Power regulator P02 (P00 P10) cycle of 30 minutes Temperature setback Adjustable within temperature range Temperature setback activation Pilot wire/Z-Wave user interface Thermo-Floor AS can not be held liable for typographical errors, other errors or omittances in our information.