Z-Wave SR-ZV9092A User Manual

Z-Wave SR-ZV9092A User Manual

Heating thermostat

Advertisement

Quick Links

Z-Wave Heating Thermostat SR-ZV9092A
Important: Read All Instructions Prior to Installation
Function introduction
LED Display
TIME/SHIFT button, to set
time schedule of the
device quickly and move
the cursor
Mode button, to switch
operation modes and quit
10 mm 10 mm
31 mm
Floor temp sensor
09.ZV9092A.04770
Home Interface
Function button, to
confirm, save setting
Move up and move down
F
buttons
Front side
80 mm
59 mm
SR-ZV9092A
NTC
L
L N N
AC Power input
Output
Back side
Product Data
Z-Wave Frequency
868.42MHz (EU)
Input Voltage
EU: AC200-240V, 50/60Hz
Output Voltage
EU: AC200-240V
3680W @ 230V (resistive load)
Max Load
Max Current
16A
Power Consumption
<2W
Ambient Temperature
0°C to 40°C (during operation)
Set Temperature Range
0°C to 40°C
Hysteresis
0.5°C to 2°C (default 0.5°C)
1. NTC/10K B(25/50 )=3950 (default)
2. NTC/15K B(25/50℃)=3950
Floor sensor type
3. NTC/50K B(25/50℃)=3950
4. NTC/100K B(25/50℃)=3950
OFF, HEAT, ENERGY HEAT, AWAY, DRY
Control Mode
Control type means which temperature sensor the device refers to
when it adjust temperature.
Room sensor: adjust temperature refers to room temperature
(factory default type).
Control Type
Floor sensor: adjust temperature refers to floor temperature.
Room+Floor sensor: adjust temperature refers to both room
temperature and floor temperature.
Current ≤ 13A - 1.5mm² solid core wire
Wiring Requirement
Current > 13A to 16A - 2.5mm² solid core wire
IP Rating
IP21
Control Pollution Degree (Method D)
pollution degree 2
Rated Impulse Voltage (Method D)
4kV
Relative Humidity
8% to 80%
Dimensions
80x80x52mm
Z-Wave Plus, CE,
LVD: EN 60730-1:2016;A1, EN IEC 60730-2-9:2019;A1
EMC & RF: EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019,
EN 60730-1:2016+A1:2019, EN 60730-2-
Approvals
19:2019+A1:2019+A2:2020, EN 50663:2017;ETSI EN 301 489-
1V2.2.3, ETSI EN301 489-3V2.1.1
ETSI EN300 220-1 v3.1.1., ETSI EN300 220-2 V3.2.1
RED certificate: 2014/53/EU
• The Z-Wave HVAC controller is a wireless thermostat for heating system, which complies to Z-Wave Plus
wireless protocol standards. The thermostat has 4 operation modes which can be controlled manually and
locally or through remote controlled through Z-Wave primary controller (gateway).

Advertisement

loading

Summary of Contents for Z-Wave SR-ZV9092A

  • Page 1 Floor temp sensor AC Power input Output • The Z-Wave HVAC controller is a wireless thermostat for heating system, which complies to Z-Wave Plus wireless protocol standards. The thermostat has 4 operation modes which can be controlled manually and Back side...
  • Page 2: Basic Function Introduction

    Manual (Comfort Mode): the device will control the heating system according to current set temperature. The as repeaters regardless of vendor to increase reliability of the network. temperature can be set by move up and move down button on the Home interface, or configured by Z-Wave gateway.
  • Page 3: Monitor Set

    Schedule setting method 2: on Home Interface, meanwhile the device is under Auto Mode , short press Short press button to select the item would like to modify, then short press button to enter into Auto Mode Schedule weekly setting interface quickly: move up and move down buttons to modify value of selected item, then On Auto Mode Schedule weekly setting interface, use buttons...
  • Page 4 1.Z-Wave Network Management NTC 10K/25 (3m,NTC,R25=10KΩ±1%@25℃, B25/50=3950K±1%) Select ZWAVE INFO on Home Interface to enter into Z-Wave network management interface as follow: Key vibration level (Low by default) Set the level of vibration sensor under the buttons or buzzer level.
  • Page 5 Set the device operation mode as Comfort Mode (Manual Mode) by sending command class basic set = 0XFF. COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION Set the device operation mode as OFF mode by sending command class basic set = 0x00. COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_VERSION Z-Wave Technical Specifications COMMAND_CLASS_MANUFACTURER_SPECIFIC 1.Supported Notification Repoert and Sensor Type COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_POWERLEVEL...
  • Page 6 ℃ COMMAND_CLASS_SUPERVISION High temperature detection max. value, unit is , when either temperature sensor is higher than this value, the device will turn off the relay and send NOTIFICATION 0x06(6) Monitor Set 0, disable this function COMMAND_CLASS_SENSOR_MULTILEVEL 20-60, the high temperature value COMMAND_CLASS_ASSOCIATION Temperature control hysteresis value setting, setting range 0.5℃...
  • Page 7: Troubleshooting

    0x1A(26) Monitor Set 0, disbaled 3-8, the set temperature threshold SR-ZV9092A Troubleshooting: 1. External (floor) sensor temperature tolerance is too big Possible reason: the selected sensor type is not correct 2. The gateway can not set temperature when energy save mode is selected...