Association Group_1; Auto Report); C Or; Association Group_2 - Z-Wave ZTS-500 User Manual

Smart
Table of Contents

Advertisement

- The "✔" symbol will be displayed on screen
once the ZTS-500 is excluded from the network.
The Z-Wave disconnect icon will also be
displayed in the standby screen.
4
- The "x" symbol will be displayed on screen if
there is no action (time out) or unable to
exclude the ZTS-500 from the network.
Note:
All Z-Wave configuration parameter values will keep no changes after excluding the unit from the
network, except for the association groups information. The ZTS-500 will retain the last selected
HVAC system type.

Support for Association Groups

ZTS-500 supports 3 association groups:
Association group
Mode
Heating mode
Cooling mode
OFF
Association group_1 (Auto report):
Association Group-1 is a default status report channel in Z-Wave+ lifeline requirement.
ZTS-500 will trigger AUTO report function if one of below status is changed.
a)
Operation mode (Off, Heat, Cool, Auto)
b)
Operation state (Heat on or off, Cool on or off)
c)
Fan mode (Auto, On, High, Low)
d)
Fan state (Fan on, Fan off)
e)
Heat set point (report in precision of 0.5

Association group_1

(Auto Report)

-
-
-
(basic set command 0x00)

Association group_2

(Heater)
ON
(basic set command 0xFF)
OFF
(basic set command 0x00)
OFF
o
o

C or 1

F)
26

Association group_3

(Compressor)
OFF
(basic set command 0x00)
ON
(basic set command 0xFF)
OFF
(basic set command 0x00)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zts-500us

Table of Contents