Z-Wave ZTS-500 User Manual page 29

Smart
Table of Contents

Advertisement

in motel service, advance user
or administrator can limit the
lower cool set point)
Reset filter counter
Set filter counter
Report filter counter
(read only)
Sensor temperature calibration
(This parameter is used to
change the display temperature
to match with your previous
thermostat, or to match
another thermostat already in
your home.
LED brightness level
7 (0x07)
8 (0x08)
9 (0x09)
10 (0x0A)
11 (0x0B)
29
o
Example 68
F; input = 680 (0x02A8)
Unit in C:
o
Range from (5
C + dead band) to 37
o
Default = 7
C
o
Example 20
C; input = 200 (0x00C8)
0 (0x00) (default)
500 (0x01F4) to 4000 (0x0FA0) hours
500 (0x01F4) hours (default)
Resolution = 1 (0x0001) hours
0 (0x0000) to 9999 (0x270F) hours
Temperature offset value.
Formula:
Display temperature = sensor reading value +
offset value
(unit = degree F)
o
0 (0x00) = 0
F (Default)
o
o
1 (0x01) = 1
F (0.5
C)
o
o
2 (0x02) = 2
F (1.0
C)
o
o
3 (0x03) = 3
F (1.5
C)
o
o
4 (0x04) = 4
F (2.0
C)
o
o
5 (0x05) = 5
F (2.5
C)
o
o
6 (0x06) = 6
F (3.0
C)
o
o
7 (0x07) = 7
F (3.5
C)
o
o
8 (0x08) = 8
F (4.0
C)
o
o
9 (0x09) = 9
F (4.5
C)
o
o
10 (0x0A) = 10
F (5.0
C)
o
o
-1 (0xFF) = -1
F (-0.5
C)
o
o
-2 (0xFE) = -2
F (-1.0
C)
o
o
-3 (0xFD) = -3
F (-1.5
C)
o
o
-4 (0xFC) = -4
F (-2.0
C)
o
o
-5 (0xFB) = -5
F (-2.5
C)
o
o
-6 (0xFA) = -6
F (-3.0
C)
o
o
-7 (0xF9) = -7
F (-3.5
C)
o
o
-8 (0xF8) = -8
F (-4.0
C)
o
o
-9 (0xF7) = -9
F (-4.5
C)
o
o
-10 (0xF6) = -10
F (-5.0
C)
1 (0x01) = Level-1 (dark)
o
C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zts-500us

Table of Contents