PLUMBING CONNECTIONS:
WARNING: Plumbing connections must comply with applicable
Sanitary, Safety and Plumbing Codes.
Two water lines are provided. Connect water supply lines to the 3/8" copper tubes at the rear of
the steamer.
One line is for supply of water to the generator and one for cold condensate water to condense
live steam entering the drain line.
DRAIN CONNECTIONS:
Appliance drain is 2 inch pipe size. Provide open air gap type drain.
WARNING: An open gap floor drain is required immediately below
the appliance drain.
CAUTION: PVC OR CPVC are not acceptable materials for drains.