MCD Soft Starter Features and Specifi cations
MCD 201
•
Soft start/stop:
Timed voltage ramp
•
Motor protection: not included
•
System protection:
not included
•
Metering: not included
•
Start/stop control: via inputs or via
optional controller
•
Network communication: optional
•
Bypass: Internally bypassed
MCD 202
•
Soft start: Current limit
•
Soft stop: Timed voltage ramp
•
Motor protection:
Thermistor, Motor overload, Phase
imbalance
•
System protection: Phase rotation,
Excess start time, Bypass overload &
Instantaneous overload
•
Metering: optional extra
•
Start/stop control: via inputs or via
optional controller
•
Network communication: optional
•
Bypass: Internally bypassed
MCD 201 and MCD 202
•
Current: 7.5 kW ~ 110 kW @400 V
•
Mains voltage: 200 ~ 575 VAC
•
Supply frequency: 45 ~ 66 Hz
•
Enclosure: 7.5 ~ 55 kW IP20,
75 ~ 110 kW IP00