Chapter 2 Preparations
1.17.2
Replacing/removing failed non-redundant fan unit
Replace the fan unit only when it fails.
1.
Power off the server.
2.
Disconnect AC power cord from power supply unit.
3.
To remove the fan unit, reverse the installation procedure.
1.17.3
Installing hot-plug redundant fan unit
Install redundant fan unit in the following procedure.
1.
Refer to steps 1 to 7 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
Insert hooks of rear fan (120 mm sq.) on the fan holder into mounting holes at rear of the server.
Mounting holes
(2 places)
Hooks (2 places)
3.
Push the fixing claw on rear fan case (120 mm sq.) to mounting holes at rear of the server until they click.
The rear fan holder is fixed to the chassis.