FLEXANALOG ITEMS
Address
FlexAnalog name
6366
SRC 4 I_1 Angle
A
6367
SRC 4 I_2 Mag
6369
SRC 4 I_2 Angle
6370
SRC 4 Igd Mag
6372
SRC 4 Igd Angle
6400
SRC 5 Ia RMS
6402
SRC 5 Ib RMS
6404
SRC 5 Ic RMS
6406
SRC 5 In RMS
6408
SRC 5 Ia Mag
6410
SRC 5 Ia Angle
6411
SRC 5 Ib Mag
6413
SRC 5 Ib Angle
6414
SRC 5 Ic Mag
6416
SRC 5 Ic Angle
6417
SRC 5 In Mag
6419
SRC 5 In Angle
6420
SRC 5 Ig RMS
6422
SRC 5 Ig Mag
6424
SRC 5 Ig Angle
6425
SRC 5 I_0 Mag
6427
SRC 5 I_0 Angle
6428
SRC 5 I_1 Mag
6430
SRC 5 I_1 Angle
6431
SRC 5 I_2 Mag
6433
SRC 5 I_2 Angle
6434
SRC 5 Igd Mag
6436
SRC 5 Igd Angle
6464
SRC 6 Ia RMS
6466
SRC 6 Ib RMS
6468
SRC 6 Ic RMS
6470
SRC 6 In RMS
6472
SRC 6 Ia Mag
6474
SRC 6 Ia Angle
6475
SRC 6 Ib Mag
6477
SRC 6 Ib Angle
6478
SRC 6 Ic Mag
6480
SRC 6 Ic Angle
6481
SRC 6 In Mag
6483
SRC 6 In Angle
6484
SRC 6 Ig RMS
6486
SRC 6 Ig Mag
6488
SRC 6 Ig Angle
6489
SRC 6 I_0 Mag
6491
SRC 6 I_0 Angle
6492
SRC 6 I_1 Mag
6494
SRC 6 I_1 Angle
A-4
Units
Description
Degrees
Source 4 positive-sequence current angle
Amps
Source 4 negative-sequence current magnitude
Degrees
Source 4 negative-sequence current angle
Amps
Source 4 differential ground current magnitude
Degrees
Source 4 differential ground current angle
Amps
Source 5 phase A current RMS
Amps
Source 5 phase B current RMS
Amps
Source 5 phase C current RMS
Amps
Source 5 neutral current RMS
Amps
Source 5 phase A current magnitude
Degrees
Source 5 phase A current angle
Amps
Source 5 phase B current magnitude
Degrees
Source 5 phase B current angle
Amps
Source 5 phase C current magnitude
Degrees
Source 5 phase C current angle
Amps
Source 5 neutral current magnitude
Degrees
Source 5 neutral current angle
Amps
Source 5 ground current RMS
Amps
Source 5 ground current magnitude
Degrees
Source 5 ground current angle
Amps
Source 5 zero-sequence current magnitude
Degrees
Source 5 zero-sequence current angle
Amps
Source 5 positive-sequence current magnitude
Degrees
Source 5 positive-sequence current angle
Amps
Source 5 negative-sequence current magnitude
Degrees
Source 5 negative-sequence current angle
Amps
Source 5 differential ground current magnitude
Degrees
Source 5 differential ground current angle
Amps
Source 6 phase A current RMS
Amps
Source 6 phase B current RMS
Amps
Source 6 phase C current RMS
Amps
Source 6 neutral current RMS
Amps
Source 6 phase A current magnitude
Degrees
Source 6 phase A current angle
Amps
Source 6 phase B current magnitude
Degrees
Source 6 phase B current angle
Amps
Source 6 phase C current magnitude
Degrees
Source 6 phase C current angle
Amps
Source 6 neutral current magnitude
Degrees
Source 6 neutral current angle
Amps
Source 6 ground current RMS
Amps
Source 6 ground current magnitude
Degrees
Source 6 ground current angle
Amps
Source 6 zero-sequence current magnitude
Degrees
Source 6 zero-sequence current angle
Amps
Source 6 positive-sequence current magnitude
Degrees
Source 6 positive-sequence current angle