10

List of parameters for control P320 / P321

.02
1
101
102
103
104
105
106
107
108
109
110
111
112
113
116
2
201
The operator has free access to the "100" parameters.
Parameters "200" - "800" can only be changed after entering a code number
and many only be changed by authorised personnel.
Pedal controlled start backtack
(I = OFF , II = ON)
Reverse rotation (I = OFF , II = ON)
Placed stitch (I = OFF , II = ON)
Bobbin thread monitoring
(0 = Off, 1 = Counter)
Bobbin thread counter (2500 ME PREMIUM only)
Bobbin thread remaining counter
(2500 ME PREMIUM only)
Stitch length adjustment (2500 ME PLUS only)
Display main processer software version
Display step motor processor software version
Display control panel software version
Display sewing drive component software
version
Control panel key tone (2500 PREMIUM only),
(I = OFF , II = ON)
Control panel key tone when moving from
one area to another (2500 PREMIUM only),
(I = OFF , II = ON)
Display serial number of machine
Machine confi guration
8 = 2571, 2591,
9 = 2571, 2591 with photo cell,
10 = reserved,
11 = reserved,
12 = 2574
13 = 2574 with photo cell
Input
I - II
I
I - II
I
I - II
I
0 - 1
1
0 - 99999
12000
0 - 999
100
-0,2 - +0,2 mm
0
I - II
II
I - II
I
-
-
8 - 14
8
43