Download Print this page

High Iops Solutions - Infortrend EonStor DS 3000 Series Quick Reference Manual

Hide thumbs Also See for EonStor DS 3000 Series:

Advertisement

High IOPS Solutions

Model
Form Factor
Storage Controller
Host connectivity
(
per ctrl.
)
Drive connectivity
*2
Expansion Channel
(
per ctrl.
)
Onboard GbE ports
(per ctrl.)
.RAID 0, 1, (0+1), 3, 5, 6,10, 30, 50, 60 with local spare, global spare, and enclosure spare drives
.Multiple RAID logical drives (LD), logical volumes (LV), partitions, host IDs, host LUNs, instant RAID ready, LD configuration on disks, dynamic
RAID Functions
host LUN mappings
.Host-side redundant path and load balancing supported (EonPath software required in the host computers) , switched fabric support, fabric
log-in(supported on fibre-host model)
Advanced Functions
.Dual-mode RAID expansion ""Add-in Drive"" and ""Copy & Replace with large drive"
.Redundant models: Auto-sync firmware and configuration on replacement controller
.LCD front panel: Easy-to-use menu for accessing all functions and features
.RS-232 Terminal: User friendly menu-driven for accessing all functions and features
Management
.SANWatch: Storage management suite. (Storage management, central view, and Notification manager via e-mail, LAN broadcast, SNMP trap,
Skype and fax)
.Embedded RAIDWatch: Storage management, event notifications (e-mail, SNMP trap, etc.) via HTTP
Management via Built-in
.Telnet-terminal: User-friendly menu-driven for accessing all function and feature via telnet
LAN
.Local replication (snapshot, volume copy and volume mirror)
Data services
.Thin provisioning: "Just-in-time" capacity allocation optimizes storage utilization and ellimates allocated but unused storage space
Hot Swap Cooling Modules
Hot Swap Power Supplies
Cache Memory*3
Cache backup*4
Accessory Variations (INC: Included, OPT: Optional)
Controller Module
(w/cache memory)
Host board
System/drawer FAN Module
Power supply module
Drive tray/drive locker
MUX board
Fibre SFP
RS-232 Cable
Cable
Rackmount Kits*5
Cache Momery*3
BBU or CBM*4
CD, Manual & Quick
Installation Guide*6
* 1. Host-side dual-loop is supported by using multi-path software on the OS or EonPath to provide path redundancy. Drive-side dual-loop is supported by RAID controllers with Fibre Channel drive side connecting.
RAID controller provides redundant path and dynamic load balancing across dual-loops.
* 2. SAS expansion ports connect SAS JBOD when there is a need to expand subsystem capacity.
* 3. We do not recommend using 3rd-party memory module due to compatibility issues. Please contact Infortrend for compatible memory modules.
* 4. There two cache backup methods. One is battery backup, providing power to cache memory during power outages. Another is cache backup module, providing power to save cache memory data into a flash
module during power outages. A cache backup module(CBM)consists of a BBU and Flash module.
* 5. For details about rackmount kits, please refer to page 15.
* 6. All hardware and software manuals are provided in PDF format in the product CD and SANWatch CD. The Quick Installation Guide (QIG) provides basic steps to set up and configure the subsystem and activate
the software licenses. For detailed functions and settings, please refer to the hardware and software manual.
ESDS 3012RT
2U-12bay LFF
Dual-redundant
4 x 8Gb FC ports
2 x 16Gb FC ports
4 x 1Gb iSCSI ports
2 x 10Gb iSCSI ports (SFP+ or RJ-45)
2 x 6Gb SAS ports
2 (embedded in PSU)
2 x 530W
2GB, 4GB, 8GB or 16GB DDR-III
CBM
85SC30RI12MB (w/2GB)
85SC30RI12MC (w/2 x 2GB)
85SC30RI12MD (w/2 x 4GB)
85SC30RI12MF (w/2 x 8GB)
RFC08G0HIO4 (8Gb FC, OPT)
RFC16G0HIO2 (16Gb FC, OPT)
RER01G0HIO4 (1Gb iSCSI, OPT)
RER10G0HIO2 (10Gb iSCSI RJ-45, OPT)
RES10G0HIO2 (10Gb iSCSI SFP+, OPT)
RSS06G0HIO2 (6Gb SAS, OPT)
9373CDTray (INC x 12)
9373CDHTray (OPT)
9373CMUX3G (OPT)
9370CSFP8G (8Gb FC, OPT)
9370CSFP16G (16Gb FC, OPT)
9370CSFP10G (10Gb ISCS SFP+, OPT)
9373AYCAB (INC x 1)
9270CFCCab04 (1M FC cable, OPT)
9270CFCCab05 (5M FC cable, OPT)
9270CFCCab06 (10M FC cable, OPT)
9270CmSASCab7 (0.5M SAS cable, OPT)
9270CmSASCab6 (1.7M SAS cable, OPT)
9270CmSASCab8 (1.2M SAS cable, OPT)
9270CmSASCab9 (2.6M SAS cable, OPT)
DDR3NNCMB2 (2GB DDR-III)
DDR3NNCMC4 (4GB DDR-III)
DDR3NNCMD (8GB DDR-III)
9383CCBM (INC x 2)
9383CBBU (OPT)
ESDS 3012GT
Single
6Gb SAS
1 x 6Gb SAS port
85SC30GI12MB (w/2GB)
85SC30GI12MC (w/2 x 2GB)
85SC30GI12MD (w/2 x 4GB)
85SC30GI12MF (w/2 x 8GB)
Embedded in PSU
9373CPSU (INCx2)
9373ASCAB (OPT)
9373CSlider36 (INC x 1)
QIG (INC x 1)
CD (INC x 2)
6
ESDS 3016RT
3U-16bay LFF
Dual-redundant
4 x 8Gb FC ports
2 x 16Gb FC ports
4 x 1Gb iSCSI ports
2 x 10Gb iSCSI ports (SFP+ or RJ-45)
2 x 6Gb SAS ports
2 (embedded in PSU)
2 x 530W
2GB, 4GB, 8GB or 16GB DDR-III
CBM
83SC30RI16MB (w/2GB)
83SC30RI16MC (w/2 x 2GB)
83SC30RI16MD (w/2 x 4GB)
83SC30RI16MF (w/2 x 8GB)
RFC08G0HIO4 (8Gb FC, OPT)
RFC16G0HIO2 (16Gb FC, OPT)
RER01G0HIO4 (1Gb iSCSI, OPT)
RER10G0HIO2 (10Gb iSCSI RJ-45, OPT)
RES10G0HIO2 (10Gb iSCSI SFP+, OPT)
RSS06G0HIO2 (6Gb SAS, OPT)
9373CDTray (INC x 16)
9373CDHTray (OPT)
9373CMUX3G (OPT)
9370CSFP8G (8Gb FC, OPT)
9370CSFP16G (16Gb FC, OPT)
9370CSFP10G (10Gb ISCS SFP+, OPT)
9373AYCAB (INC x 1)
9270CFCCab04 (1M FC cable, OPT)
9270CFCCab05 (5M FC cable, OPT)
9270CFCCab06 (10M FC cable, OPT)
9270CmSASCab7 (0.5M SAS cable, OPT)
9270CmSASCab6 (1.7M SAS cable, OPT)
9270CmSASCab8 (1.2M SAS cable, OPT)
9270CmSASCab9 (2.6M SAS cable, OPT)
DDR3NNCMB2 (2GB DDR-III)
DDR3NNCMC4 (4GB DDR-III)
DDR3NNCMD (8GB DDR-III)
9383CCBM (INC x 2)
9383CBBU (OPT)
ESDS 3016GT
Single
83SC30GI16MB (w/2GB)
83SC30GI16MC (w/2 x 2GB)
83SC30GI16MD (w/2 x 4GB)
83SC30GI16MF (w/2 x 8GB)
9373ASCAB (OPT)

Advertisement

loading