5.10.3.3
Braking position (MB)
At this master position, the slave comes to a standstill after decoupling (MB > MT
possible).
Standstill position Slave (S0)
Target position of the slave axis after decoupling.
Back stop
The back stop can be enabled if required (IEC module C3_MasterControl (see
page 237)).
It ensures that a backwards movement of the master will not incite an axis
movement of the slave.
Example:
Pos
1
3
4
1: Master signal after back stop
2: Master signal before back stop
3: Backwards movement of the master
4: Forwards movement of the master corresponding to the backwards movement.
The negative distance difference caused by the backwards movement of the
master (3) must be traveled in positive direction (4), before it can be effective as a
movement.

Basic procedure

When implementing a standard cam application, the following steps are necessary:
Create curve and load into Compax3.
Setting the master position detection
Establish relationship between master position read in and curve.
Select curve.
Start curve operation in a defined fashion.
Establish relationship with slave position (coupling).
Finish curve operation in a defined fashion (decoupling).